JetClean 智氫潔離子源
Agilent JetClean 離子源利用軟件控制的氫氣流來減少或防止污染物積聚并消除離子源中的基質(zhì)沉積物。JetClean 的自動(dòng)清潔離子源功能不僅可以延長儀器的正常運(yùn)行時(shí)間,還可以生成更加一致的數(shù)據(jù)、減少重復(fù)工作,讓您在節(jié)省成本的同時(shí)對(duì)結(jié)果更加充滿信心。
- GC/MS 離子源和進(jìn)樣口
產(chǎn)品詳細(xì)信息
- 手動(dòng)清潔頻率降低 80% 或更多(取決于具體應(yīng)用),顯著延長免維護(hù)運(yùn)行周期
- 顯著縮短甚至消除儀器在放空、拆卸、清潔、重新組裝、重新調(diào)諧和重新校準(zhǔn)上所耗費(fèi)的時(shí)間,延長儀器正常運(yùn)行時(shí)間,減少操作人員的工作量,從而提高效率
- 無需人工干預(yù),即可在預(yù)設(shè)時(shí)間點(diǎn)自動(dòng)激活 JetClean,例如在空閑時(shí)間段內(nèi)
- 使用?采集和清潔?(并行)模式在分析期間進(jìn)行清潔,或使用?僅清潔?(運(yùn)行后)模式,僅在系統(tǒng)需要清潔時(shí),在采集后引入氫氣進(jìn)行清潔
- 僅需消耗極少的 H2。氫氣可以通過氣閥瓶等多種方式提供。
- 操作均由 Agilent MassHunter 軟件控制,從而可輕松實(shí)現(xiàn)采集控制、方法開發(fā)、定性和定量分析以及報(bào)告。單四極桿儀器也由 OpenLab 2.3 軟件進(jìn)行類似控制
- 適用于 Agilent 5977C、7000E 和 7010D GC/MS 系統(tǒng)。Agilent Intuvo、8890 和 7890 GC 也可兼容 JetClean 運(yùn)行
- 可作為現(xiàn)有 Agilent 5975、5977、7000 和 7010 氣質(zhì)聯(lián)用系統(tǒng)的升級(jí)
- 重要資料
-
Agilent JetClean self-cleaning ion source for GC/MS e-book
Save Time and Money with the Agilent JetClean Self-Cleaning Ion Source for GC/MS
- 產(chǎn)品樣本
- English
- 2021 年 5 月 5 日
- 642.18 KB
- 應(yīng)用簡報(bào)
- 產(chǎn)品樣本
- 案例研究
- 宣傳單頁
- 掛圖
- 用戶手冊
-
Agilent JetClean Operating Manual, Chinese
This manual contains information for operating and maintaining the Agilent JetClean System.
- 用戶手冊
- Chinese (Simplified)
- 2024 年 12 月 31 日
- 1.67 MB
Agilent JetClean Operating Manual, English
This manual contains information for operating and maintaining the Agilent JetClean System.
- 用戶手冊
- English
- 2024 年 12 月 31 日
- 1.42 MB
Dr. Noga Sikron Persi, PhD
Ben-Gurion University Metabolomics Laboratory
"The nature of our work meant we had to clean the ion source on our previous, non-Agilent GC/MS about once every 2 weeks. Since we started using the Agilent GC/MSD with JetClean, the source has been cleaned once in 9 months meaning our instrument spends more time running samples and generating data—and our users spend less time having to remove, clean, and reinstall the source. JetClean has been a tremendous benefit on instrument uptime and lab productivity."
查看更多Jana Pulkrabova, Ph. D.
Head of the Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague
"Our laboratory carries out pesticide residue analysis with the Agilent 7000 GC/MS/MS. The samples include common fruits and vegetables, but we also analyze more difficult herbal samples, and monitor baby food, which has lower detection requirements. To satisfy SANCO defined QA/QC specifications with these varied samples, the GC/MS source usually had to be cleaned every 2 weeks. After installing the JetClean system, the frequency of the manual source cleaning has been greatly reduced, we now manually clean the source only once in every 3 months. This increased productivity and freed up operator time is greatly appreciated."
查看更多Klaus Wilmers, PhD
Chemical and Veterinary Analytical Institute Muensterland-Emscher-Lippe (CVUA-MEL), Muenster, Germany
"We analyzed the EN QuEChERS in various food extracts – e.g. chard, apple, plum, peppers and spinach in the working range of 0.1 – 250 ppb (in vial) using internal standards, Analyte Protectants and employing the high efficiency source. Without JetClean, manual source cleaning was needed after 200-300 matrix runs. Applying JetClean after each run, manual cleaning was only needed after 600-900 matrix runs, thus, instrument up-time was increased by several-fold and associated cost-savings were realized."
查看更多