Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
- Detection Technique
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
Agilent J&W HP-PLOT Q PT and HP-PLOT U PT GC columns were evaluated for coal-to-chemical process gas analysis by GC/TCD and GC/MS detection.
- Publication Part Number: 5991-2205EN
- Created: 03 Apr 2013
- 262 KB
19095P-QO4+19095P-UO4+
| Publication Part Number | 5991-2205EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates carbonyl sulfide and ethylene in seven minutes.
- Publication Part Number: A01260
- Created: 31 Oct 2011
- 486 KB
CP8567+
| Publication Part Number | A01260 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-SilicaPLOT column identifies 3 ppm COS in propylene in less than five minutes.
- Publication Part Number: A01270
- Created: 31 Oct 2011
- 296 KB
CP8567+
| Publication Part Number | A01270 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gaseous impurities in ethylene in less than three minutes.
- Publication Part Number: A01273
- Created: 31 Oct 2011
- 296 KB
CP6954+
| Publication Part Number | A01273 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
本應(yīng)用簡(jiǎn)報(bào)介紹了在燃料電池研究和開發(fā)及 β 測(cè)試中使用安捷倫微型氣相色譜儀分析氣體組分。
- Publication Part Number: 5991-3364CHCN
- Created: 01 Dec 2014
- 1 MB
| Publication Part Number | 5991-3364EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|