Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Detection Technique
- Method
- Analysis Platform
-
Product
- Language
-
Language
Effective analysis of multiple pesticides in water used an Agilent 5975T LTM GC/MSD with stir bar sorptive extraction and a Thermal Separation Probe.
- Publication Part Number: 5991-4264EN
- Created: 14 Mar 2014
- 230 KB
| Publication Part Number | 5991-4264EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for GC Analysis of Halogenated Pesticides using the Agilent J&W FactorFour VF-1701ms with EZ-Guard
- Publication Part Number: SI-02247
- Created: 29 Jan 2014
- 150 KB
| Publication Part Number | SI-02247 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Using GC/MS, an Agilent J&W VF-200ms column separates 16 organochlorine pesticides according to EPA625 in 27 minutes.
- Publication Part Number: A02092
- Created: 31 Oct 2011
- 612 KB
| Publication Part Number | A02092 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 19 organochlorine pesticides according to EPA 8080 in 50 minutes.
- Publication Part Number: A0796
- Created: 31 Oct 2011
- 528 KB
| Publication Part Number | A00796 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of 16 organochlorine pesticides according to EPA 625 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02208
- Created: 31 Oct 2011
- 886 KB
| Publication Part Number | A02208 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Sixteen organochlorine pesticides are analyzed by GC using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms in less than 27 minutes.
- Publication Part Number: A02283
- Created: 31 Oct 2011
- 778 KB
| Publication Part Number | A02283 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
| Publication Part Number | A00805 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
| Publication Part Number | A00789 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
| Publication Part Number | A00780 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB/C18 column separates organic pollutants in whale blubber in 95 minutes.
- Publication Part Number: A0978
- Created: 31 Oct 2011
- 822 KB
| Publication Part Number | A00978 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|