Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Injection Technique
-
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C2 to C7 free fatty acids in water in seven minutes.
- Publication Part Number: A0281
- Created: 20 June 2014
- 711 KB
| Publication Part Number | A00281 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for analyzing Liquid Fractions of Biogas Processes by HPLC
- Publication Part Number: SI-01943
- Created: 29 Jan 2014
- 201 KB
| Publication Part Number | SI-01943 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates 40 C2 to C20 free fatty acids in milk fat (with volatile acids added) in 60 minutes.
- Publication Part Number: A0362
- Created: 31 Oct 2011
- 881 KB
| Publication Part Number | A00362 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 105 components in an apricot purée.
- Publication Part Number: A1023
- Created: 31 Oct 2011
- 3 MB
| Publication Part Number | A01023 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine C2 to C7 volatile fatty acids in water in 12 minutes.
- Publication Part Number: A0122
- Created: 31 Oct 2011
- 532 KB
| Publication Part Number | A00122 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates nine C2 to C10 free fatty acids in a wine distillate in nine minutes.
- Publication Part Number: A0364
- Created: 31 Oct 2011
- 781 KB
| Publication Part Number | A00364 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 15 C2 to C18 free fatty acids in 14 minutes.
- Publication Part Number: A0126
- Created: 31 Oct 2011
- 654 KB
| Publication Part Number | A00126 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 37 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01420
- Created: 31 Oct 2011
- 873 KB
| Publication Part Number | A01420 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W FFAP column separates eight volatile C2 to C7 free fatty acids in 15 minutes.
- Publication Part Number: A00097
- Created: 31 Oct 2011
- 561 KB
| Publication Part Number | A00097 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
使用Agilent 5975T LTM GCMS 分析脂肪酸甲酯
- Publication Part Number: 5991-1437CHCN
- Created: 09 Nov 2012
- 254 KB
| Publication Part Number | 5991-1437EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||