Refine Results
- Products
- Applications and Industries
- Content Type
-
Applications (7)
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Injection Technique
- Instrument
-
- Analysis Platform
-
DB-624 Ultra Inert Columns (2) 7697A Headspace Sampler (1)
Product
- Language
-
English (7) Japanese (1) Chinese (Simplified) (2)
Language
Applied Filters
An Agilent J&W DB-624UI column was compared with non-Agilent 624 phases, delivering better performance for C3 through C8 volatiles.
- Publication Part Number: 5991-1441EN
- Created: 08 Nov 2012
- 622 KB
| Publication Part Number | 5991-1441EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
The inertness of Agilent J&W DB-624UI gives excellent peak shape and sensitivity for active aldehydes and organic acids in complex beer matrices, for straightforward profiling
- Publication Part Number: 5991-1136EN
- Created: 08 Oct 2012
- 978 KB
| Publication Part Number | 5991-1136EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Gas chromatography using an Agilent J&W CP-FFAP column separates 40 C2 to C20 free fatty acids in milk fat (with volatile acids added) in 60 minutes.
- Publication Part Number: A0362
- Created: 31 Oct 2011
- 881 KB
| Publication Part Number | A00362 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 alcohols and esters in a sample of Chateau Ventenac 1988 red wine in 45 minutes.
- Publication Part Number: A0469
- Created: 31 Oct 2011
- 783 KB
| Publication Part Number | A00469 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates nine C2 to C10 free fatty acids in a wine distillate in nine minutes.
- Publication Part Number: A0364
- Created: 31 Oct 2011
- 781 KB
| Publication Part Number | A00364 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 15 C2 to C18 free fatty acids in 14 minutes.
- Publication Part Number: A0126
- Created: 31 Oct 2011
- 654 KB
| Publication Part Number | A00126 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 37 silylated organic acids in urine in 70 minutes.
- Publication Part Number: A01420
- Created: 31 Oct 2011
- 873 KB
| Publication Part Number | A01420 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|