This application note highlights percentage level analysis of hydrogen on an Agilent Micro GC using a mixed carrier gas.
- Publication Part Number: 5991-3199EN
- Created: 24 Oct 2013
- 761 KB
| Publication Part Number | 5991-3199EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01237
- Created: 31 Oct 2011
- 343 KB
| Publication Part Number | A01237 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01242
- Created: 31 Oct 2011
- 382 KB
| Publication Part Number | A01242 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
| Publication Part Number | A00755 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC with Agilent J&W CarboBOND separates eight C1-C3 hydrocarbons in less than seven minutes. Water elutes before propane with virtually no effect on retention time.
- Publication Part Number: A01651
- Created: 31 Oct 2011
- 812 KB
| Publication Part Number | A01651 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC with an Agilent CP-Molsieve 5? column module and Agilent 490 Micro GC separates neon, nitrogen, hydrogen and argon in a xenon test mix in 66 seconds.
- Publication Part Number: A0871
- Created: 31 Oct 2011
- 441 KB
| Publication Part Number | A00871 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01238
- Created: 31 Oct 2011
- 357 KB
| Publication Part Number | A01238 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note for Permanent Gas Analysis – Separation of Argon and Oxygen on a MolSieve 5A Column using the Agilent 490 Micro GC
- Publication Part Number: 5990-8700EN
- Created: 27 July 2011
- 200 KB
| Publication Part Number | 5990-8700EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|