Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Detection Technique
- Injection Technique
- Instrument
- Method
- Language
-
Language
Applied Filters
The seamless transfer of the EPA method (8330A/B) from the Agilent 1200 Series Rapid Resolution LC (RRLC) to the Agilent 1290 Infinity Binary LC using ISET is demonstrated
- Publication Part Number: 5991-1194EN
- Created: 15 Sep 2014
- 873 KB
| Publication Part Number | 5991-1194EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Separation of 19 nitro-aromatics using automated consecutive injections on two columns with different separation mechanism.
- Publication Part Number: 5991-3212EN
- Created: 01 Oct 2013
- 5 MB
| Publication Part Number | 5991-3212EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The EPA 8330A analysis of nitroaromatics and nitramines explosive residues was improved by using a Poroshell 120 EC-CN column for confirmation and a Poroshell 120 EC-C18
- Publication Part Number: 5991-1682EN
- Created: 20 Dec 2012
- 542 KB
| Publication Part Number | 5991-1682EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
| Publication Part Number | A02097 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
| Publication Part Number | A02090 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC separation of 13 nitro and sulfur compounds according to EPA 8270 is achieved in 20 minutes with an J&W Agilent VF-17ms column.
- Publication Part Number: A02279
- Created: 31 Oct 2011
- 965 KB
| Publication Part Number | A02279 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
GC with direct injection of nitro and halogenated aromatic compounds (base neutrals) is accomplished by the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02295
- Created: 31 Oct 2011
- 753 KB
| Publication Part Number | A02295 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Nitro aromatics and cyclic ketones are analyzed by GC according to EPA 8090 using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02285
- Created: 31 Oct 2011
- 700 KB
| Publication Part Number | A02285 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Agilent ACE Partner Edition
- Publication Part Number: 5991-2981KO
- Created: 13 Dec 2013
- 1 MB
| Publication Part Number | 5991-2981EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Portuguese (Brazil) | Complete (PDF) |
|---|---|
| French (France) | Complete (PDF) |
| German (Germany) | Complete (PDF) |
| Spanish (Spain) | Complete (PDF) |
| Italian (Italy) | Complete (PDF) |