note cites and is supported by a VOC kit that contains the necessary parts to implement this VOC solution set.
- Publication Part Number: 5991-0029EN
- Created: 23 June 2015
- 4 MB
| Publication Part Number | 5991-0029EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
UHPLC and LC/MS analysis of carbonyls by Poroshell 120 EC-C18 gave good selectivity and resolution.
- Publication Part Number: 5991-2125EN
- Created: 19 Mar 2013
- 785 KB
| Publication Part Number | 5991-2125EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates acrolein and acrylonitrile according to EPA 603 in ten minutes.
- Publication Part Number: A0782
- Created: 31 Oct 2011
- 375 KB
| Publication Part Number | A00782 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
| Publication Part Number | A01505 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC separation of 37 oxygenated compounds on a highly selective Agilent J&W Lowox multilayer column is achieved in 45 minutes.
- Publication Part Number: A02251
- Created: 31 Oct 2011
- 874 KB
| Publication Part Number | A02251 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates acrolein, acrylonitrile and acetonitrile according to EPA 8030 in nine minutes.
- Publication Part Number: A0793
- Created: 31 Oct 2011
- 399 KB
| Publication Part Number | A00793 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates 21 alcohols and esters in ‘fire water’ in 21 minutes.
- Publication Part Number: A0619
- Created: 31 Oct 2011
- 854 KB
| Publication Part Number | A00619 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
| Publication Part Number | A00804 | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC analyzes acrolein in air in 20 seconds.
- Publication Part Number: A0876
- Created: 31 Oct 2011
- 261 KB
| Publication Part Number | A00876 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 organic solvents in 35 minutes.
- Publication Part Number: A0493
- Created: 31 Oct 2011
- 671 KB
| Publication Part Number | A00493 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 23 volatile organic compounds in air in 60 minutes.
- Publication Part Number: A01890
- Created: 01 Oct 2011
- 882 KB
| Publication Part Number | A01890 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates two oxygenated compounds in air in 40 minutes.
- Publication Part Number: A01889
- Created: 01 Oct 2011
- 753 KB
| Publication Part Number | A01889 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|