Refine Results
- Products
- Applications and Industries
- Content Type
-
Applications (5)
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Analysis Platform
-
7693A Automatic Liquid Sampler (1) Capillary Flow Technology (1) GC/MS/MS Pesticides Analyzer (1) Multimode Inlet (1) Multimode Inlet (archive) (1)
Product
- Language
-
English (4) Korean (1) Chinese (Simplified) (2)
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
19091S-431UI+5982-5058+5982-5755+G3903-61005+
| Publication Part Number | 5991-4131EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Fifteen days’ exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
121-0722+121-5523UI+
| Publication Part Number | 5991-4110EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A method has been developed on the Agilent 5977A Series GC/MSD that enables MDLs and RSDs for six phthalates
- Publication Part Number: 5991-1810EN
- Created: 26 Mar 2013
- 843 KB
| Publication Part Number | 5991-1810EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A method has been developed on the Agilent 5977A Series GC/MSD for the detection of 16 PAHs at levels as low as 5 parts per billion (ppb)
- Publication Part Number: 5991-1811EN
- Created: 21 Jan 2013
- 173 KB
| Publication Part Number | 5991-1811EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
本文使用帶高靈敏的Extractor EI 離子源的Agilent 5977A 系列GC/MSD,利用非目標(biāo)化合物分析和統(tǒng)計(jì)工具,對(duì)化合物進(jìn)行分析,以區(qū)分五種不同品牌的威士忌。
- Publication Part Number: 5991-2547CHCN
- Created: 14 June 2013
- 866 KB
19091N-202+
| Publication Part Number | 5991-2547EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|