Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An analytical method that is well established for the 7000 Series Triple Quadrupole GC/MS has been employed to demonstrate performance of the 7000C Triple Quadrupole GC/MS.
- Publication Part Number: 5991-4131EN
- Created: 21 Mar 2014
- 180 KB
| Publication Part Number | 5991-4131EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Fifteen days’ exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
| Publication Part Number | 5991-4110EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
| Publication Part Number | 5991-2153EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
A method has been developed on the Agilent 5977A Series GC/MSD that enables MDLs and RSDs for six phthalates
- Publication Part Number: 5991-1810EN
- Created: 26 Mar 2013
- 843 KB
| Publication Part Number | 5991-1810EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
A method has been developed on the Agilent 5977A Series GC/MSD System that can provide detection of N-nitrosamines in water at sub-part per trillion (ppt) levels
- Publication Part Number: 5991-1970EN
- Created: 12 Feb 2013
- 81 KB
| Publication Part Number | 5991-1970EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
A method has been developed on the Agilent 5977A Series GC/MSD for the detection of 16 PAHs at levels as low as 5 parts per billion (ppb)
- Publication Part Number: 5991-1811EN
- Created: 21 Jan 2013
- 173 KB
| Publication Part Number | 5991-1811EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
?? 5ppb ??, SVOC 30? ??? ?? Agilent 5977A ??? GC/MSD? ??? ???? ??? ??? ? ???? ????.
- Publication Part Number: 5991-2127KO
- Created: 05 Mar 2019
- 2 MB
| Publication Part Number | 5991-2127EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
帶 7697A 頂空進樣器的安捷倫氣質(zhì)聯(lián)用血液酒精濃度分析儀能夠滿足毒理學(xué)家快速、準(zhǔn)確和精確地測量血液中乙醇含量的需求。
- Publication Part Number: 5991-4059CHCN
- Created: 19 May 2014
- 4 MB
| Publication Part Number | 5991-4059EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Agilent 5977A GC/MSD を用いたウィスキーの香気成分のケモメトリクスプロファイリング
- Publication Part Number: 5991-2547JAJP
- Created: 08 Aug 2013
- 1 MB
| Publication Part Number | 5991-2547EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|