Revident LC/Q-TOF 和 1290 Infinity III HPLC
Revident LC/Q-TOF 系統(tǒng)
提高分析效率的創(chuàng)新技術(shù)包括可大大延長(zhǎng)儀器正常運(yùn)行時(shí)間的 Intelligent Reflex、在需要時(shí)提供理想性能的預(yù)約調(diào)諧和校準(zhǔn),以及針對(duì)不同用戶角色量身定制的新型采集軟件。所有新功能相結(jié)合可實(shí)現(xiàn)更高的通量,從而提升實(shí)驗(yàn)室的盈利能力。
- Quadrupole Time of Flight LC/MS
Product Details
- 高分辨 (Hi-Res) 質(zhì)譜篩查可用于顯著提高含大量疑似物的樣品的檢測(cè)能力,包括使用完整質(zhì)譜信息進(jìn)行回顧性分析
- 使用非數(shù)據(jù)依賴型采集模式同時(shí)進(jìn)行常規(guī)篩查和定量,可靈敏地檢測(cè)和鑒別污染物,并保持高采集速率的出色性能
- 通過(guò)預(yù)約調(diào)諧和校準(zhǔn)、早期維護(hù)反饋和儀器診斷實(shí)現(xiàn)理想儀器性能,提高您的實(shí)驗(yàn)室分析效率
- Intelligent Reflex 工作流程包括殘留、飽和信號(hào)的自動(dòng)再進(jìn)樣,快速篩查、疑似物篩查確認(rèn)以及迭代 MS/MS,使儀器能夠在您專注于結(jié)果的同時(shí)連續(xù)采集數(shù)據(jù)
- 全新且直觀的質(zhì)譜采集軟件與 LC/TQ UI 保持一致,并針對(duì)不同的實(shí)驗(yàn)室角色(從技術(shù)人員到實(shí)驗(yàn)室經(jīng)理和審計(jì)員)進(jìn)行了簡(jiǎn)化和定制
- 新的軟件工作流程可實(shí)現(xiàn)無(wú)縫批處理和統(tǒng)計(jì)分析,并通過(guò)顯著性分析對(duì)化合物進(jìn)行后續(xù)鑒定,從而優(yōu)化未知物鑒定
- 包括回讀在內(nèi)的創(chuàng)新模塊化設(shè)計(jì)代表了高度復(fù)雜且完整的儀器診斷功能,可持續(xù)監(jiān)測(cè)所有相關(guān)信息,從而能夠快速且可靠地檢測(cè)各個(gè)組件的狀態(tài)
- 基于模擬數(shù)字轉(zhuǎn)換 (ADC) 的全新檢測(cè)器可生成具有高分辨率和同位素保真度的質(zhì)量峰,獲得的峰對(duì)稱性確保了不同豐度水平的高質(zhì)量準(zhǔn)確度
- 用于校準(zhǔn)液和參考質(zhì)量標(biāo)樣的新型輸送系統(tǒng)采用基于泵的流量控制,可提供恒定且可靠的流速
| IDL 靈敏度(正離子) |
|
| IDL 靈敏度(負(fù)離子) |
|
| MS 靈敏度(正離子) |
|
| MS 靈敏度(負(fù)離子) |
|
| MS 質(zhì)量準(zhǔn)確度(正離子) |
|
| MS 質(zhì)量準(zhǔn)確度(負(fù)離子) |
|
| MS 采集速率 |
|
| MS/MS 靈敏度(正離子) |
|
| MS/MS 靈敏度(負(fù)離子) |
|
| MS/MS 質(zhì)量準(zhǔn)確度(正離子) |
|
| MS/MS 質(zhì)量準(zhǔn)確度(負(fù)離子) |
|
| MS/MS 采集速率 |
|
| TOF 質(zhì)量分辨率 (FWHM) |
|
| TOF 質(zhì)量范圍 |
|
| 同位素保真度 |
|
| 四極桿分離質(zhì)量范圍 |
|
| 四極桿分辨率 (FWHM) |
|
| 支持的附加軟件 |
|
| 無(wú)需放真空的維護(hù) |
|
| 極性切換占空比 |
|
| 溫度質(zhì)量穩(wěn)定性 |
|
| 離子源 |
|
| 譜圖內(nèi)動(dòng)態(tài)范圍 |
|
| 軟件平臺(tái) |
|
- Application Notes
-
An End-to-End Untargeted LC/MS Workflow for Metabolomics and Lipidomics
An end-to-end workflow for sample prep, instrumental analysis, and untargeted data analysis for metabolomics and lipidomics from plasma or mammalian cell samples.
- Application Notes
- English
- 07 Jul 2025
- 2.06 MB
Expanding PFAS Coverage in Nontargeted Analysis Using Data-Independent Analysis
Expanding PFAS Coverage in Nontargeted Analysis Using Data-Independent Analysis
- Application Notes
- English
- 26 Feb 2025
- 1.24 MB
Toxicological Drug Screening Using the LC Screener Tool with High-Resolution LC/Q-TOF
Toxicological drug screening workflow using the LC Screener tool.
- Application Notes
- English
- 05 Dec 2024
- 1.07 MB
Targeted Data Mining and Annotation of Untargeted High-Resolution Lipidomics Data
Application note documenting a curated, high confidence lipidomics workflow for LC/Q-TOF.
- Application Notes
- English
- 27 Aug 2024
- 2.18 MB
Illuminating the Cellular and Molecular Response to Drug Treatment by Combining Bioenergetic Measurements with LC/MS Omics
Cellular-resolution Agilent Seahorse XF bioenergetic analyses were combined with molecular-resolution Agilent Revident Q-TOF LC/MS to investigate adaptations in cancer cells.
- Application Notes
- English
- 01 Aug 2024
- 2.99 MB
Pesticide Screening in Food Matrices Using Agilent Revident LC/Q-TOF
This application note details a method for pesticide screening in complex food matrices using the Agilent Revident LC/Q-TOF with MassHunter Quantitative Analysis.
- Application Notes
- English
- 13 May 2024
- 1.82 MB
- Brochures
- Posters
- Technical Overviews
Videos
- Support
-
MassHunter Acquisition Software for LC/MS Installation Guide
This guide provides instructions for installing MassHunter Data Acquisition for LC/TQ 12.1 or higher and MassHunter Data Acquisition for LC/(Q-)TOF 12.0 or higher.
- Installation Guides
- English
- 05 Nov 2024
- 4.18 MB
Revident LC/QTOF Introduction Workbook
This workbook serves as a companion to the introduction delivered at installation for the Revident LC/Q-TOF system running MassHunter Data Acquisition 12.0 or higher.
- User Manuals
- English
- 08 Sep 2025
- 5.02 MB
- Site Preparation Checklists
- User Manuals
Workflows for Non-Targeted Analysis of PFAS in Biological Matrices
This webinar explores a comprehensive non-targeted workflow using high-resolution mass spectrometry and FluoroMatch Suite software that overcomes this limitation.
The PFAS legacy in our urban environment
Per- and polyfluoroalkyl substances (PFAS) are emerging contaminants attracting global scientific and regulatory attention due to their environmental persistence and bioaccumulative properties.
Revident LC/Q-TOF 獲得 My Green Lab 的 ACT 標(biāo)簽
My Green Lab 的 ACT 標(biāo)簽由 SMS Collective, LLC (SMSC) 獨(dú)立審核,并由 My Green Lab 發(fā)布,該標(biāo)簽提供了相關(guān)產(chǎn)品在其整個(gè)生命周期中對(duì)環(huán)境造成的影響的信息。My Green Lab 是一家致力于提高科學(xué)研究可持續(xù)性的非營(yíng)利組織。
- 21 Nov 2024