Refine Results
- Products
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Evaluating 209 PCBs congeners by GC/MS using the Agilent 8890/5977C GC/MSD equipped with the Agilent HydroInert ion source and Agilent J&W DB-XLB column.
- Publication Part Number: 5994-8541EN
- Created: 22 Aug 2025
- 631 KB
Meet the Agilent 7000E and 7010C triple quadrupole GC/MS systems. The 7000E provides robust, day-in, day-out performance, while the 7010C is designed for analyses that demand the lowest limits of detection.
- Publication Part Number: 5994-4921EN
- Created: 29 July 2025
- 23 MB
Ethylene oxide (EO) and 1,4-dioxane are critical industrial chemicals often found as residuals in surfactant production.
- Publication Part Number: 5994-8335EN
- Created: 18 July 2025
- 534 KB
The benefits of hydrogen in gas chromatography (GC) are widely accepted - it can be generated in the lab in a cost-effective manner, and it produces fast chromatography and higher sample throughput.
- Publication Part Number: 5994-7680EN
- Created: 06 Aug 2024
- 278 KB
This application note shows the analysis of phthalate with hydrogen carrier gas using the Agilent HydroInert source on a challenging cable sample in GC/MS.
- Publication Part Number: 5994-7215EN
- Created: 18 Mar 2024
- 429 KB
Examination of Mass Spectra of Aroma Components in Essential Oils via GC/MS by using HydroInert Ion Source Specifically for Use with Hydrogen as a Carrier Gas
- Publication Part Number: 5994-5818EN
- Created: 06 Feb 2024
- 1 MB
| Japanese (Japan) | Complete (PDF) |
|---|
This application demonstrates that hydrogen carrier gas, when paired with the Agilent HydroInert source, is a viable option for the analysis of terpenes in cannabis flower.
- Publication Part Number: 5994-7040EN
- Created: 09 Jan 2024
- 578 KB
This application note demonstrates residual solvents analysis (RSA) using headspace as a sample introduction technique on a single quadrupole GC/MS in selective ion monitoring (SIM) mode with hydrogen as the GC carrier gas.
- Publication Part Number: 5994-7034EN
- Created: 01 Jan 2024
- 7 MB
This application note outlines the translation of a GC/MS forensic drug screening method from using helium to hydrogen carrier gas by applying the HydroInert source.
- Publication Part Number: 5994-6982EN
- Created: 20 Dec 2023
- 2 MB
Hydrogen carrier gas for analyzing pesticides in pigmented foods with 8890/7000E and 8890/7010C GC/TQ systems GC/MS/MS.
- Publication Part Number: 5994-6505EN
- Created: 19 July 2023
- 4 MB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
| Korean (Korea) | Complete (PDF) |
This application note summarizes the analysis of terpenes in cannabis using GC/MS with hydrogen carrier gas and the Agilent HydroInert source.
- Publication Part Number: 5994-6511EN
- Created: 12 July 2023
- 308 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note summarizes the analysis of terpenes in cannabis using gas chromatography/mass spectrometry with hydrogen carrier gas.
- Publication Part Number: 5994-6216EN
- Created: 08 June 2023
- 397 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note describes the use of hydrogen carrier gas and the Agilent HydroInert source for GC/MS analysis of humidified canister ‘a(chǎn)ir toxics’ samples at 100% relative humidity, using cryogen-free systems for thermal desorption...
- Publication Part Number: 5994-5359EN
- Created: 31 May 2023
- 1 MB
The Agilent HydroInert source was used in the system evaluated here for analyzing F&F mixtures.
- Publication Part Number: 5994-6015EN
- Created: 23 May 2023
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Korean (Korea) | Complete (PDF) |
A GC/MS/MS method for polycyclic aromatic hydrocarbon (PAH) analysis in a complex soil matrix using hydrogen carrier gas and the Agilent HydroInert source.
- Publication Part Number: 5994-5776EN
- Created: 02 Mar 2023
- 450 KB
This application note focuses on GC/MS in selected ion monitoring (SIM) mode using hydrogen as the GC carrier gas.
- Publication Part Number: 5994-5711EN
- Created: 14 Feb 2023
- 654 KB
This technical overview evaluates the application of the Agilent HydroInert source to Agilent Inert Plus GC/MS analyses.
- Publication Part Number: 5994-4889EN
- Created: 07 Nov 2022
- 1 MB
Meet the Agilent 5977C GC/MSD. The 5977C is designed to provide robust, day-in, day-out performance so you can focus on what matters.
- Publication Part Number: 5994-4922EN
- Created: 25 Oct 2022
- 4 MB
A quick start guide for the Agilent HydroInert Source installation.
- Publication Part Number: 5994-5315EN
- Created: 21 Oct 2022
- 2 MB
The purpose of this document is to help users of Agilent EI GC/MS systems determine if hydrogen can be used as a carrier gas for their analyses and what considerations and procedures are necessary to make the transition successful.
- Publication Part Number: 5994-2312EN
- Created: 01 Oct 2022
- 1 MB