Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Isobaric ppb PAHs are separated in cocoa and peanut by SIM GC/MS with a short Agilent J&W Select PAH GC column and Agilent Bond Elut SPE, with co-extracted triglycerides.
- Publication Part Number: 5991-2299EN
- Created: 07 May 2013
- 651 KB
| Publication Part Number | 5991-2299EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Analysis of PAHs using a VF-17ms Column with EZ-Guard.
- Publication Part Number: SI-02221
- Created: 27 Sep 2012
- 136 KB
| Publication Part Number | SI-02221 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 16 polycyclic aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A0679
- Created: 31 Oct 2011
- 786 KB
| Publication Part Number | A00679 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 polycyclic aromatic hydrocarbons according to EPA 610 in 60 minutes.
- Publication Part Number: A0704
- Created: 31 Oct 2011
- 597 KB
| Publication Part Number | A00704 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
For GC analysis of 16 polyaromatic hydrocarbons use an Agilent J&W VF-200ms column to achieve a separation in 30 minutes.
- Publication Part Number: A2202
- Created: 31 Oct 2011
- 496 KB
| Publication Part Number | A02202 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 41 organic water pollutants according to EPA 525 in 50 minutes.
- Publication Part Number: A0781
- Created: 31 Oct 2011
- 797 KB
| Publication Part Number | A00781 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil PAH CB UltiMetal column separates 16 polyaromatic hydrocarbons according to EPA 610 in 58 minutes.
- Publication Part Number: A00586
- Created: 31 Oct 2011
- 577 KB
| Publication Part Number | A00586 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of 16 polyaromatic hydrocarbons according to EPA 610 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02209
- Created: 31 Oct 2011
- 940 KB
| Publication Part Number | A02209 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with an Agilent J&W VF-Xms column separates 13 polycyclic aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A01962
- Created: 31 Oct 2011
- 806 KB
| Publication Part Number | A01962 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The Agilent J&W VF-17ms GC column separates 16 polycyclic aromatic hydrocarbons in 40 minutes.
- Publication Part Number: A02274
- Created: 31 Oct 2011
- 773 KB
| Publication Part Number | A02274 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
| Publication Part Number | A00805 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Analyze polycyclic aromatic hydrocarbons with Agilent J&W VF-5ms and oncolumn injection to avoid discrimination, adsorption, or decomposition in hot injection ports.
- Publication Part Number: A02253
- Created: 31 Oct 2011
- 2 MB
| Publication Part Number | A02253 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 20 polycyclic aromatic hydrocarbons according to EPA 8100 in 45 minutes.
- Publication Part Number: A0801
- Created: 31 Oct 2011
- 553 KB
| Publication Part Number | A00801 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Describes the use of Ultra Inert liners to analyze Endrin and DDT. The results indicate superior analysis of the active compounds.
- Publication Part Number: 5990-7380EN
- Created: 01 Apr 2011
- 428 KB
| Publication Part Number | 5990-7380EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
LZ
- Publication Part Number: 5990-7381EN
- Created: 08 Mar 2011
- 285 KB
| Publication Part Number | 5990-7381EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
437A.jpg
- Publication Part Number: 19091S-433
- Created: 08 May 2018
- 49 KB
- JPG
| Publication Part Number | 437A | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
- Publication Part Number: 5990-7380CHCN
- Created: 09 Mar 2011
- 788 KB
| Publication Part Number | 5990-7380EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|