Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Compounds
-
- Injection Technique
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
GC analysis of mineral oil in soil or water is achieved in eight minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02016
- Created: 31 Oct 2011
- 587 KB
| Publication Part Number | A02016 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The analysis of mineral oil can be done with high efficiency using GC and the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02046
- Created: 31 Oct 2011
- 698 KB
| Publication Part Number | A02046 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
| Publication Part Number | A01322 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 components in a sample of crude oil in 50 minutes.
- Publication Part Number: A00096
- Created: 31 Oct 2011
- 845 KB
| Publication Part Number | A00096 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Fast GC analysis of lubricating oil contamination in under ten minutes using an Agilent J&W Select Mineral Oil column according to DIN EN ISO 9377-2.
- Publication Part Number: A02048
- Created: 31 Oct 2011
- 684 KB
| Publication Part Number | A02048 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Application note for High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System
- Publication Part Number: 5990-9104EN
- Created: 23 Sep 2011
- 312 KB
| Publication Part Number | 5990-9104EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
Determination of hydrocarbons and lubricating oil in soil according to DIN H53 using an Agilent J&W VF-5ms GC column.
- Publication Part Number: A02332
- Created: 11 May 2010
- 1 MB
| Publication Part Number | A02332 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|