GC with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC separates hydrogen, oxygen, nitrogen, helium, and neon in 70 seconds.
- Publication Part Number: A0860
- Created: 31 Oct 2011
- 374 KB
| Publication Part Number | A00860 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5? analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
| Publication Part Number | A01619 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC separates spiked neon and hydrogen in air in 39 seconds.
- Publication Part Number: A0866
- Created: 31 Oct 2011
- 421 KB
| Publication Part Number | A00866 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC detects low ppm levels of hydrogen in helium/neon in 30 seconds.
- Publication Part Number: A0864
- Created: 31 Oct 2011
- 255 KB
| Publication Part Number | A00864 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
GC with an Agilent CP-Molsieve 5? column module and Agilent 490 Micro GC separates neon, nitrogen, hydrogen and argon in a xenon test mix in 66 seconds.
- Publication Part Number: A0871
- Created: 31 Oct 2011
- 441 KB
| Publication Part Number | A00871 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|