Refine Results
- Products
- Content Type
-
Content Type
- Analysis Technique
- Compounds
-
Compounds
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Analysis of five nitrosamines in sartan drugs using the published GC-MS/MS FDA method
- Publication Part Number: 5994-1821EN
- Created: 22 Apr 2020
- 306 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
Describes the use of the Agilent 8890 GC to analyze impurities in sartan products according to a United States Food and Drug Administration (US FDA) method.
- Publication Part Number: 5994-1132EN
- Created: 03 Mar 2020
- 347 KB
A GC/FID/MSD method for the residual solvents.
- Publication Part Number: 5994-1488EN
- Created: 15 Nov 2019
- 1 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Extractables were identified in pressurized metered dose inhaler components using two Agilent 5977A Series GC/MSD Systems.
- Publication Part Number: 5991-6142EN
- Created: 09 Oct 2015
- 671 KB
GC/Q-TOF MS data was used for identification and quantitation, while MSMS data was used to predict the impuriy fragment structures using MSC software.
- Publication Part Number: 5991-6058EN
- Created: 29 July 2015
- 1 MB
| Korean (Korea) | Complete (PDF) |
|---|
Plasticizers were identified in drug suspension using headspace GC/MS and MMI GC/MS. SIM confirmed the identification of phthalate and fatty acid plasticizers.
- Publication Part Number: 5991-5632EN
- Created: 22 July 2015
- 597 KB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
propylene oxide impurities were analyzed with low method-detection limit, good resolution, sample recovery, and repeatability using Agilent J&W PoraBOND U.
- Publication Part Number: 5991-6074EN
- Created: 20 July 2015
- 77 KB
The analysis of Class1, Class 2A, and Class 2B residual solvents are demonstrated at USP 467 limit concentrations using the 5977 MSD with the 7890B and 7697A Headspace sampler
- Publication Part Number: 5991-2079EN
- Created: 21 Mar 2013
- 2 MB
| Publication Part Number | 5991-2079EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
USP residual solvents were analyzed by static headspace on the Agilent 7697A Headspace Sampler combined with the Agilent 7890B Gas Chromatograph.
- Publication Part Number: 5991-1834EN
- Created: 29 Jan 2013
- 340 KB
| Publication Part Number | 5991-1834EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|