This application note establishes a process for identifying GC-amenable extractables and leachable compounds using GC/MSD and GC/Q-TOF instruments.
- Publication Part Number: 5994-7777EN
- Created: 10 Sep 2024
- 3 MB
This application note demonstrates the use of the Agilent 8890 GC system coupled with an FID detector to detect and quantify ethylene glycol and diethylene glycol in propylene glycol, glycerin and syrup samples.
- Publication Part Number: 5994-7159ENIN
- Created: 01 Feb 2024
- 3 MB
Increase performance and productivity for your analysis of residual solvents with Agilent J&W DB-Select 624 Ultra Inert for and DB-WAX Ultra Inert columns.
- Publication Part Number: 5991-8659EN
- Created: 01 Oct 2021
- 3 MB
A method for the analysis of residual solvents by USP Method with the Agilent 8890 GC and selected columns.
- Publication Part Number: 5994-0442EN
- Created: 16 May 2019
- 2 MB
Residual Solvent Analyzer dramatically reduces the time for validation of a new system.
- Publication Part Number: 5991-8460EN
- Created: 30 Nov 2017
- 1 MB
Agilent Intuvo 9000 GC system—a new breed of GC system from the industry leader in GC innovation
- Publication Part Number: 5991-7273EN
- Created: 25 Aug 2016
- 1 MB
Agilent J&W CP-Select 624 Hexane is dedicated to separate dichloromethane and hexane in India. Every column is tested and guaranteed for consistent performance.
- Publication Part Number: 5991-6144EN
- Created: 09 Nov 2015
- 846 KB
propylene oxide impurities were analyzed with low method-detection limit, good resolution, sample recovery, and repeatability using Agilent J&W PoraBOND U.
- Publication Part Number: 5991-6074EN
- Created: 20 July 2015
- 77 KB
7820GC and 7697A HSS for residual solvents analysis in packaging material
- Publication Part Number: 5991-2044EN
- Created: 21 Mar 2013
- 667 KB
| Publication Part Number | 5991-2044EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Specifically designed and tested Agilent J&W DB-Select 624UI for USP resolves critical pairs.
- Publication Part Number: 5991-0616EN
- Created: 07 June 2012
- 2 MB
| Publication Part Number | 5991-0616EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This study demonstrates how unit resolution GC/MS workflow is employed for identifying GC-amenable E&L compounds by leveraging spectral deconvolution in combination with retention index-based time filtering.
- Publication Part Number: ASMS 2024 MP208
- Created: 31 May 2024
- 1 MB