Using the Agilent 1290 Infinity II Bio LC System and Agilent AdvanceBio SEC 200 ? 1.9 μm PEEK-lined column in mAbs analysis.
- Publication Part Number: 5994-5674EN
- Created: 27 Jan 2023
- 572 KB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Measuring thermal-induced protein aggregation provides insight into the stability of highly concentrated mAb samples in a formulation buffer.
- Publication Part Number: 5994-4944EN
- Created: 20 July 2022
- 2 MB
This application note presents different approaches to native mass spectrometry.
- Publication Part Number: 5994-3036EN
- Created: 25 Mar 2021
- 2 MB
The Agilent 1220 Infinity II LC offers reliable and robust profiling and quantification for 11 of the most commonly targeted cannabinoids found in cannabis sativa.
- Publication Part Number: 5991-9285EN
- Created: 22 May 2020
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note describes a robust LC/MS method for the analysis of native protein analysis.
- Publication Part Number: 5994-1739EN
- Created: 12 Mar 2020
- 948 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
Comparision of innovator and bisosimilar pair using Agilent Cary 60 UV-Vis spectrophotometer
- Publication Part Number: 5991-7026EN
- Created: 17 Feb 2020
- 984 KB
| Korean (Korea) | Complete (PDF) |
|---|
Critical Quality Attribute Monitoring of mAbs at the Intact and Subunit Levels
- Publication Part Number: 5994-1349EN
- Created: 06 Dec 2019
- 611 KB
The development and manufacturing of biosimilars require comparability studies with innovator biotherapeutic products.
- Publication Part Number: 5994-1496EN
- Created: 25 Oct 2019
- 2 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Presents a method for protein analysis using an Agilent LC/MSD XT and 1260 Infinity II LC.
- Publication Part Number: 5994-0188EN
- Created: 17 July 2019
- 249 KB
Presents the use of the AdvanceBio HIC column to resolve monoclonal antibody variants from their native form without mAb digestion into subunits.
- Publication Part Number: 5994-0199EN
- Created: 10 July 2019
- 628 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
Presents the use of the Agilent Bio SEC-3 column to aid HRMS characterization of mAbs and ADCs.
- Publication Part Number: 5994-0303EN
- Created: 01 Nov 2018
- 2 MB
Presents the use of AdvanceBio Desalting-RP cartridges to pretreat mAb and ADC samples before MS analysis.
- Publication Part Number: 5994-0302EN
- Created: 01 Nov 2018
- 2 MB
Agilent PLRP-S column demonstrates superior separation performance for the analysis of mAbs and ADC at both intact and fragment levels
- Publication Part Number: 5991-7163EN
- Created: 01 Aug 2016
- 288 KB
Agilent AdvanceBioSEC columns used for fast, high resolution, sensitive, and reproducible separation and quantitation of mAbs and Antibody Drug Conjugate,
- Publication Part Number: 5991-7165EN
- Created: 01 Aug 2016
- 905 KB
Comparative analysis using LC-QTOF/MS between innovator and biosimilar of Rituximab
- Publication Part Number: 5991-6522EN
- Created: 01 Jan 2016
- 1 MB
| Korean (Korea) | Complete (PDF) |
|---|
This Application Note demonstrates the sensitive and reproducible analysis of N-linked glycans of human immunoglobulin G with a novel HILIC column and fluorescence detection.
- Publication Part Number: 5991-4801EN
- Created: 01 Nov 2015
- 840 KB
| Publication Part Number | 5991-4801EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Agilent Bio Mab WCX separates charged variants of papain-digest monoclonal antibody, following by MS characterization of the charged variants with online desalting.
- Publication Part Number: 5991-5274EN
- Created: 04 Nov 2014
- 279 KB
Innovator and biosimilar biotherapeutic rituximab monoclonal antibodies were compared using the Agilent 1260 Infinity Multi-Detector Bio-SEC Solution.
- Publication Part Number: 5991-5220EN
- Created: 01 Oct 2014
- 998 KB
A versatile Agilent Bio-Monolith Protein A column analyzed an optimized recombinant mAb manufactured with desired structural characteristics.
- Publication Part Number: 5991-5125EN
- Created: 29 Aug 2014
- 187 KB
This work describes a high flow LCMS method to demonstrate the high resolution mass analysis of mAbs with good chromatography and its utility in analysis of Biosimilar mAbs.
- Publication Part Number: 5991-4266EN
- Created: 01 July 2014
- 310 KB