Refine Results
- Products
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
The development and manufacturing of biosimilars require comparability studies with innovator biotherapeutic products.
- Publication Part Number: 5994-1495EN
- Created: 15 Oct 2024
- 2 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
A Comparative Study of the Intact Mass, Subunit Mass, and Released Glycans of Two Rituximab Biosimilars Using High-Resolution LC/MS
- Publication Part Number: 5994-1653EN
- Created: 15 Oct 2024
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
LC/MS based characterization workflow of the GLP-1 therapeutic peptide liraglutide and its impurities using the 1290 Infinity II LC and 6545XT AdvanceBio LC/Q-TOF.
- Publication Part Number: 5994-7727EN
- Created: 25 Sep 2024
- 3 MB
This application note utilizes the 1260 Infinity II Bio Prime LC and InfinityLab LC/MSD iQ for the confirmation of GLP-1 (Liraglutide) sample.
- Publication Part Number: 5994-7415EN
- Created: 01 May 2024
- 1 MB
An automated workflow for the analysis of protein phosphorylation from sample preparation with phosphopeptide enrichment to analysis by IMS.
- Publication Part Number: 5994-1617EN
- Created: 26 Nov 2019
- 2 MB
The development and manufacturing of biosimilars require comparability studies with innovator biotherapeutic products.
- Publication Part Number: 5994-1496EN
- Created: 25 Oct 2019
- 2 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Presents a method for peptide mapping using an Agilent LC/MSD XT and 1290 Infinity II LC.
- Publication Part Number: 5994-0990EN
- Created: 26 June 2019
- 1 MB
This app note presents a high-throughput workflow that enables simultaneous, highly reproducible sample digestion and cleanup.
- Publication Part Number: 5991-7811EN
- Created: 15 Feb 2017
- 2 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
In the current study, We present a solid method for peptide quantification using capillary LC-MS/MS, emphasizing three key analytical parameters: (1) limit of detection (LOD) and limit of quantification (LOQ), (2) linear range for multiple peptides,...
- Publication Part Number: ASMS 2024 WP587
- Created: 31 May 2024
- 263 KB
Describes the identification and quantitation of chemically-modified recombinant mABs with the Agilent 6545XT AdvanceBio LC/Q-TOF and Agilent MassHunt...
- Publication Part Number: 5994-0406JAJP
- Created: 13 Mar 2019
- 1 MB
Demonstration of robust and reliable peptide mapping and characterization of post-translational modifications in mAbs using an AdvanceBio Peptide Plus...
- Publication Part Number: 5991-8046JAJP
- Created: 09 Mar 2018
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
本應(yīng)用摘要針對序列圖譜分析提供了一套完整的高通量工作流程解決方案。
- Publication Part Number: 5991-7815CHCN
- Created: 24 Mar 2017
- 2 MB
| Japanese (Japan) | Complete (PDF) |
|---|
本文詳細(xì)的介紹了蛋白(肽段)定量的意義及出現(xiàn) MRM 質(zhì)譜技術(shù)平臺的緣由、MRM 肽段定量的基本原理、安捷倫 MRM 肽段定量的完整定義以及安捷倫 LC/QQQ 肽段定量應(yīng)用實(shí)例等。
- Publication Part Number: 5991-6988CHCN
- Created: 17 June 2016
- 5 MB