This application note highlights percentage level analysis of hydrogen on an Agilent Micro GC using a mixed carrier gas.
- Publication Part Number: 5991-3199EN
- Created: 24 Oct 2013
- 761 KB
| Publication Part Number | 5991-3199EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
This note describes the use of an Agilent 490-PRO Micro GC for the analysis of liquefied propane and butane (LPG) streams for plant quality control and plant processing.
- Publication Part Number: 5991-1972EN
- Created: 11 Mar 2013
- 449 KB
| Publication Part Number | 5991-1972EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
This application note describes the use of the Agilent 490-PRO Micro GC for the analysis of liquefied ethane product.
- Publication Part Number: 5991-1817EN
- Created: 25 Jan 2013
- 527 KB
| Publication Part Number | 5991-1817EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|
Bulk gaseous chemicals are not necessarily used close to their production site.
- Publication Part Number: 5991-1326EN
- Created: 23 Oct 2012
- 1 MB
| Publication Part Number | 5991-1326EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in 25 seconds.
- Publication Part Number: A02065
- Created: 31 Oct 2011
- 746 KB
| Publication Part Number | A02065 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Four-channel Agilent 490 Micro GC analyzes refinery gas, permanent gases, hydrogen sulfide, and all saturated and unsaturated hydrocarbons up to C5, in 150 s.
- Publication Part Number: A01786
- Created: 31 Oct 2011
- 810 KB
| Publication Part Number | A01786 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Al2O3/KCl column and Agilent 490 Micro GC separates C1 to C4 hydrocarbons in 100 seconds.
- Publication Part Number: A02067
- Created: 31 Oct 2011
- 393 KB
| Publication Part Number | A02067 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column and Agilent 490 Micro GC separates neon, oxygen, and nitrogen in 40 seconds.
- Publication Part Number: A02062
- Created: 31 Oct 2011
- 640 KB
| Publication Part Number | A02062 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in a chlor-alkali cell in 60 seconds.
- Publication Part Number: A02064
- Created: 31 Oct 2011
- 729 KB
| Publication Part Number | A02064 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column and Agilent 490 Micro GC separates carbon monoxide, oxygen, and nitrogen in 55 seconds.
- Publication Part Number: A02063
- Created: 31 Oct 2011
- 585 KB
| Publication Part Number | A02063 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
| Publication Part Number | 5990-9165EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for Permanent Gas Analysis – Separation of Argon and Oxygen on a MolSieve 5A Column using the Agilent 490 Micro GC
- Publication Part Number: 5990-8700EN
- Created: 27 July 2011
- 200 KB
| Publication Part Number | 5990-8700EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Analysis of permenant gases using 10m Molsieve column for samples with a high % of oxygen.
- Publication Part Number: 5990-8527EN
- Created: 05 July 2011
- 340 KB
| Publication Part Number | 5990-8527EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for Fast Separation of Oxygen and Nitrogen on a MolSieve 5A Channel Using the Agilent 490 Micro GC
- Publication Part Number: 5990-8529EN
- Created: 28 June 2011
- 213 KB
| Publication Part Number | 5990-8529EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the analysis of tert-Butyl Mercaptan inNatural Gas on a CP-Sil 13 CB Using the 490 GC
- Publication Part Number: 5990-8250EN
- Created: 27 May 2011
- 360 KB
| Publication Part Number | 5990-8250EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|