Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An SPME technique using a PDMS SPME Fibers for the analysis of PAHs in drinking water samples.
- Publication Part Number: 5994-1301EN
- Created: 21 Aug 2019
- 914 KB
An SPME technique using a CAR(WR)/PDMS 95 μm SPME Fiber for the analysis of BTEX in drinking water samples.
- Publication Part Number: 5994-1104EN
- Created: 13 Aug 2019
- 724 KB
An Agilent SPME Arrow is used with an Agilent PAL3 autosampler to analyze immersion extracted PAHs by GC.
- Created: 17 Mar 2019
- 313 KB
EMR-Lipid removes high-fat avocado matrix effectively, with better recovery, speed, robustness, cleanliness, excellent accuracy and precision of pesticides.
- Publication Part Number: 5991-6098EN
- Created: 04 Aug 2015
- 304 KB
Agilent Bond Elut Enhanced Matrix Removal-Lipid quantitates low to high PAH concentrations in salmon with a simple QuEChERS workflow that minimizes fat coextracts.
- Publication Part Number: 5991-6088EN
- Created: 30 July 2015
- 215 KB
Application note for the determination of Organophosphates in Lake Water
- Publication Part Number: SI-02094
- Created: 03 Feb 2014
- 167 KB
| Publication Part Number | SI-02094 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Application note for the determination of Phenols in Drinking Water with Agilent Bond Elut Plexa SPE and HPLC
- Publication Part Number: 5990-9730EN
- Created: 06 Jan 2012
- 58 KB
| Publication Part Number | 5990-9730EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS European Standard EN Kits by LC/MS/MS Detection
- Publication Part Number: 5990-3938EN
- Created: 06 Jan 2012
- 682 KB
| Publication Part Number | 5990-3938EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Application note for the analysis of Pesticide Residues in Apple by GC/MS using Agilent Bond Elut QuEChERS Kits for Preinjection Cleanup
- Publication Part Number: 5990-4468EN
- Created: 06 Jan 2012
- 217 KB
| Publication Part Number | 5990-4468EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Application note for the analysis of pesticide residues in apples using Agilent Bond Elut QuEChERS AOAC Kit by LC/MS/MS Detection
- Publication Part Number: 5990-3937EN
- Created: 06 Jan 2012
- 683 KB
| Publication Part Number | 5990-3937EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4068EN
- Created: 06 Jan 2012
- 113 KB
| Publication Part Number | 5990-4068EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
This flyer provides product and ordering information on the Agilent VersaPlate. Streamline SPE with VersaPlate to process more samples in less time with less waste.
- Publication Part Number: 5991-3846EN
- Created: 13 Jan 2014
- 2 MB