Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
-
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
The exceptional inertness of Agilent J&W DB-5ms Ultra Inert GC columns delivered superior results for basic compounds in a comparison of -5ms phases.
- Publication Part Number: 5991-4626EN
- Created: 13 May 2014
- 224 KB
| Publication Part Number | 5991-4626EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 21 phenols according to EPA 8040 in 24 minutes.
- Publication Part Number: A1001
- Created: 31 Oct 2013
- 692 KB
| Publication Part Number | A01001 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Analysis of multiple semi-volatile organic compounds by USEPA method 8270D is challenging. It was performed by GC/MS with FactorFour VF-5ms column and quadrupole MS, giving 7
- Publication Part Number: SI-2365
- Created: 01 Aug 2013
- 253 KB
| Publication Part Number | SI-02365 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
| Publication Part Number | 5991-2153EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Using the Agilent 7696A Sample Prep WorkBench to prepare calibration standards
- Publication Part Number: 5991-0973EN
- Created: 17 Aug 2012
- 684 KB
| Publication Part Number | 5991-0973EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Application note for the determination of Phenols in Drinking Water with Agilent Bond Elut Plexa SPE and HPLC
- Publication Part Number: 5990-9730EN
- Created: 06 Jan 2012
- 58 KB
| Publication Part Number | 5990-9730EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 21 phenols according to EPA 8040 in 15 minutes.
- Publication Part Number: A0794
- Created: 31 Oct 2011
- 623 KB
| Publication Part Number | A00794 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of 21 phenols with an Agilent J&W VF-200ms column achieves a separation in 22 minutes.
- Publication Part Number: A02201
- Created: 31 Oct 2011
- 623 KB
| Publication Part Number | A02201 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
| Publication Part Number | A00805 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Inertness of the Agilent J&W VF-5ms GC column is very high, as shown in the GC/MS analysis of 21 free phenols in 12 minutes, using the EPA 528 method.
- Publication Part Number: A01984
- Created: 31 Oct 2011
- 730 KB
| Publication Part Number | A01984 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 21 chlorinated phenols according to EPA 8040 in 20 minutes.
- Publication Part Number: A0912
- Created: 31 Oct 2011
- 712 KB
| Publication Part Number | A00912 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
| Publication Part Number | A00789 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with Agilent J&W CP-Sil 8 CB and CP- 5 CB columns separate 33 methyl-, nitro, and chlorophenols in river water in 35 minutes.
- Publication Part Number: A0339
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A00339 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W VF-Xms column separates 21 phenols in eight minutes.
- Publication Part Number: A01965
- Created: 31 Oct 2011
- 904 KB
| Publication Part Number | A01965 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 16 phenols according to EPA 604 in 12 minutes.
- Publication Part Number: A0618
- Created: 31 Oct 2011
- 619 KB
| Publication Part Number | A00618 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Determination of 18 chlorophenols in water and soil is straightforward on an Agilent J&W VF-5ms column in under 13 minutes.
- Publication Part Number: A02388
- Created: 11 May 2010
- 601 KB
| Publication Part Number | A02388 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
?? 5ppb ??, SVOC 30? ??? ?? Agilent 5977A ??? GC/MSD? ??? ???? ??? ??? ? ???? ????.
- Publication Part Number: 5991-2127KO
- Created: 05 Mar 2019
- 2 MB
| Publication Part Number | 5991-2127EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|