Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Compounds
-
Compounds
- Injection Technique
-
- Language
-
Language
Applied Filters
This describes a rapid & precise HPLC procedure for quantitative determination of organic acids in fruit juices under reversed-phase conditions with a100% aqueous mobile phase
- Publication Part Number: 5991-1992EN
- Created: 20 Feb 2013
- 580 KB
| Publication Part Number | 5991-1992EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates 40 C2 to C20 free fatty acids in milk fat (with volatile acids added) in 60 minutes.
- Publication Part Number: A0362
- Created: 31 Oct 2011
- 881 KB
| Publication Part Number | A00362 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 58 FFAP CB column separates 19 components in a sample of natto (fermented soy beans) in 35 minutes.
- Publication Part Number: A0854
- Created: 31 Oct 2011
- 437 KB
| Publication Part Number | A00854 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates nine C2 to C10 free fatty acids in a wine distillate in nine minutes.
- Publication Part Number: A0364
- Created: 31 Oct 2011
- 781 KB
| Publication Part Number | A00364 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W FFAP column separates eight volatile C2 to C7 free fatty acids in 15 minutes.
- Publication Part Number: A00097
- Created: 31 Oct 2011
- 561 KB
| Publication Part Number | A00097 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
解決氣相柱QC 測(cè)試中所關(guān)注的問(wèn)題
- Publication Part Number: 5990-9961CHCN
- Created: 05 Mar 2012
- 647 KB
| Publication Part Number | 5990-9961EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|