Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates alcohols in blood/plasma in three minutes.
- Publication Part Number: A01323
- Created: 25 Aug 2015
- 392 KB
| Publication Part Number | A01323 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates 21organochlorine pesticides in 40 minutes.
- Publication Part Number: A00055
- Created: 31 Oct 2011
- 780 KB
| Publication Part Number | A00055 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates 22 non-volatile organic acids in eight minutes.
- Publication Part Number: A00008
- Created: 31 Oct 2011
- 510 KB
| Publication Part Number | A00008 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates desmethyldiazepam and donazepam in 35 minutes.
- Publication Part Number: A0114
- Created: 31 Oct 2011
- 417 KB
| Publication Part Number | A00114 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates 14 steroids as their TMS derivatives in 13 minutes.
- Publication Part Number: A0115
- Created: 31 Oct 2011
- 741 KB
| Publication Part Number | A00115 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates five derivatized steroids in 17 minutes.
- Publication Part Number: A0164
- Created: 31 Oct 2011
- 505 KB
| Publication Part Number | A00164 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC separation of 12 phenols using an Agilent J&W CP-Sil 19 CB column with FID is achieved in 15 minutes.
- Publication Part Number: A01953
- Created: 31 Oct 2011
- 736 KB
| Publication Part Number | A01953 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates four C4 to C7 alcohols in water in four minutes.
- Publication Part Number: A0107
- Created: 31 Oct 2011
- 391 KB
| Publication Part Number | A00107 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates six polycyclic aromatic hydrocarbons in ten minutes.
- Publication Part Number: A0113
- Created: 31 Oct 2011
- 523 KB
| Publication Part Number | A00113 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates 23 C6 to C10 substituted aromatics and phenols in 19 minutes.
- Publication Part Number: A0197
- Created: 31 Oct 2011
- 662 KB
| Publication Part Number | A00197 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates two organochlorine pesticides in 11 minutes.
- Publication Part Number: A00074
- Created: 31 Oct 2011
- 351 KB
| Publication Part Number | A00074 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|