Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-WAX 57 CB column provides a unique selectivity in the analysis of 20 impurities in a whisky in 37 minutes.
- Publication Part Number: A01539
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01539 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with an Agilent J&W CP-Wax 57 CB column delivers excellent selectivity in the analysis of 25 impurities in an alcoholic beverage in 37 minutes.
- Publication Part Number: A01540
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01540 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates 15 aromatics and alcohol from gasoline in 28 minutes.
- Publication Part Number: A00031
- Created: 31 Oct 2011
- 724 KB
| Publication Part Number | A00031 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten C1 to C6 volatile alcohols in 1-hexanol in 15 minutes.
- Publication Part Number: A0162
- Created: 31 Oct 2011
- 860 KB
| Publication Part Number | A00162 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates seven C11 to C13 alkanes and C1 to C4 alcohols in 15 minutes.
- Publication Part Number: A00033
- Created: 31 Oct 2011
- 447 KB
| Publication Part Number | A00033 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Select 623 CB column separates 23 solvents in 20 minutes.
- Publication Part Number: A01280
- Created: 31 Oct 2011
- 855 KB
| Publication Part Number | A01280 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates 12 alcohols and aromatic hydrocarbons in a test mixture in 16 minutes.
- Publication Part Number: A0369
- Created: 31 Oct 2011
- 773 KB
| Publication Part Number | A00369 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 25 constituents in a toluene sample in 17 minutes.
- Publication Part Number: A01281
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01281 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates 12 components in gasoline in just over 10 minutes.
- Publication Part Number: A00035
- Created: 31 Oct 2011
- 665 KB
| Publication Part Number | A00035 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates four C4 to C7 alcohols in water in four minutes.
- Publication Part Number: A0107
- Created: 31 Oct 2011
- 391 KB
| Publication Part Number | A00107 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of 26 solvents used in inks is accomplished in 35 minutes with an Agilent J&W Select 624 CB column.
- Publication Part Number: A02233
- Created: 31 Oct 2011
- 742 KB
| Publication Part Number | A02233 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates ten oxygenates in 11 minutes.
- Publication Part Number: A0904
- Created: 31 Oct 2011
- 723 KB
| Publication Part Number | A00904 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
| Publication Part Number | A01546 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01424 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates several aromatics, and butanol, in 20 minutes.
- Publication Part Number: A00076
- Created: 31 Oct 2011
- 461 KB
| Publication Part Number | A00076 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 10 volatiles in ethanol in seven minutes.
- Publication Part Number: A0432
- Created: 31 Oct 2011
- 644 KB
| Publication Part Number | A00432 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 24 C6 to C9 hydrocarbons in air in 12.5 minutes.
- Publication Part Number: A01526
- Created: 31 Oct 2011
- 734 KB
| Publication Part Number | A01526 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Si 5 CB column separates 35 solvents and contaminants in a sample of industrial waste water in 18 minutes.
- Publication Part Number: A01451
- Created: 31 Oct 2011
- 833 KB
| Publication Part Number | A01451 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 18 C1 to C11 volatile alcohols, ketones, and ethers in 20 minutes.
- Publication Part Number: A0157
- Created: 31 Oct 2011
- 801 KB
| Publication Part Number | A00157 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight alcohols in red wine in 16 minutes.
- Publication Part Number: A0706
- Created: 31 Oct 2011
- 521 KB
| Publication Part Number | A00706 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|