Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-WAX 57 CB column provides a unique selectivity in the analysis of 20 impurities in a whisky in 37 minutes.
- Publication Part Number: A01539
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01539 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with an Agilent J&W CP-Wax 57 CB column delivers excellent selectivity in the analysis of 25 impurities in an alcoholic beverage in 37 minutes.
- Publication Part Number: A01540
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01540 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
UofG
- Publication Part Number: SI-00989
- Created: 05 Dec 2011
- 270 KB
| Publication Part Number | SI-00989 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
HJ
- Publication Part Number: SI-00940
- Created: 05 Dec 2011
- 164 KB
| Publication Part Number | SI-00940 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Wax 52 CB column identifies dimethylsulfide in a sample of beer in 15 minutes.
- Publication Part Number: A00006
- Created: 31 Oct 2011
- 449 KB
| Publication Part Number | A00006 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 22 alcohols and esters in a wine distillate in 34 minutes.
- Publication Part Number: A0416
- Created: 31 Oct 2011
- 748 KB
| Publication Part Number | A00416 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 10 volatiles in ethanol in seven minutes.
- Publication Part Number: A0432
- Created: 31 Oct 2011
- 644 KB
| Publication Part Number | A00432 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Select 624 CB column separates five solvents in 18 minutes.
- Publication Part Number: A01285
- Created: 31 Oct 2011
- 644 KB
| Publication Part Number | A01285 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 11 alcohols and esters in beer in 12 minutes.
- Publication Part Number: A0620
- Created: 31 Oct 2011
- 637 KB
| Publication Part Number | A00620 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 36 solvents in 41 minutes.
- Publication Part Number: A01318
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01318 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using split injection and an Agilent J&W CP-Wax 57 CB column separates 26 alcohols and esters in a sample of whisky in 43 minutes.
- Publication Part Number: A00052
- Created: 31 Oct 2011
- 745 KB
| Publication Part Number | A00052 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax for Volatile Amines and Diamines column separates 17 alcohols and acetates in ten minutes.
- Publication Part Number: A0696
- Created: 31 Oct 2011
- 699 KB
| Publication Part Number | A00696 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 27 aromas in a wine sample in 14 minutes.
- Publication Part Number: A01461
- Created: 31 Oct 2011
- 810 KB
| Publication Part Number | A01461 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
424A.jpg
- Publication Part Number: 19091B-112
- Created: 08 May 2018
- 40 KB
- JPG
| Publication Part Number | 424A | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
428A.jpg
- Publication Part Number: 19091N-213
- Created: 08 May 2018
- 43 KB
- JPG
| Publication Part Number | 428A | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|