Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
- Compounds
-
Compounds
- Detection Technique
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W PoraBOND Q column separates hydrogen chloride and sulfuryl chloride in less than five minutes.
- Publication Part Number: A01427
- Created: 31 Oct 2013
- 581 KB
| Publication Part Number | A01427 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Monitoring oxygenates in mixed C4 streams is very important in propylene production.
- Publication Part Number: 5991-1549EN
- Created: 06 Dec 2012
- 168 KB
| Publication Part Number | 5991-1549EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Gas chromatography with an Agilent J&W PoraBOND Q column separates 13 trace C1 to C3 hydrocarbon solvents in drinking water in 11 minutes.
- Publication Part Number: A01423
- Created: 31 Oct 2011
- 878 KB
| Publication Part Number | A01423 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01424 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W PoraBOND Q column separates four trace sulfur compounds in eight minutes.
- Publication Part Number: A01458
- Created: 31 Oct 2011
- 503 KB
| Publication Part Number | A01458 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND Q column separates nine C1 to C3 hydrocarbons in ten minutes.
- Publication Part Number: A01425
- Created: 31 Oct 2011
- 678 KB
| Publication Part Number | A01425 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W PoraBOND Q column separates 13 chlorinated fluorocarbons and C1 to C6 hydrocarbons in 15 minutes.
- Publication Part Number: A01429
- Created: 31 Oct 2011
- 721 KB
| Publication Part Number | A01429 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND Q column separates ten common residual solvents in four minutes.
- Publication Part Number: A01457
- Created: 31 Oct 2011
- 452 KB
| Publication Part Number | A01457 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W PoraBOND Q column separates 33 solvents in 30 minutes.
- Publication Part Number: A01624
- Created: 31 Oct 2011
- 579 KB
| Publication Part Number | A01624 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraBOND Q column separates eight halogenated degradation products of tetrachloroethylene in surface water in 10 minutes.
- Publication Part Number: A01426
- Created: 31 Oct 2011
- 483 KB
| Publication Part Number | A01426 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Analysis of low levels of bromochloromethane in chloroform is done by GC/MS with Agilent J&W PoraBOND Q columns in 12 minutes.
- Publication Part Number: A01919
- Created: 01 Oct 2011
- 631 KB
| Publication Part Number | A01919 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|