Refine Results
- Products
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
An Agilent 7890 Series GC configured with an HPLI with post-column backflushing improves the analysis of trace hydrocarbon impurities in monomer grade 1,3-Butadiene.
- Publication Part Number: 5991-1672EN
- Created: 18 Dec 2012
- 1 MB
115-3352+19095N-121+
| Publication Part Number | 5991-1672EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
An improved gas chromatographic method based on a 7890 Series GC for the analysis of trace hydrocarbon impurities in monomer grade 1, 3-Butadiene has been developed.
- Publication Part Number: 5991-1499EN
- Created: 29 Nov 2012
- 2 MB
115-3352+
| Publication Part Number | 5991-1499EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
CP7565+
| Publication Part Number | SI-02644 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
| Publication Part Number | 5990-9165EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|