Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Injection Technique
- Language
-
Language
Applied Filters
Thick film Agilent J&W VF-200ms is very stable for analyzing aggressive compounds. For acetic acid, solubility is relatively high, which results in a narrow peak.
- Publication Part Number: A02203
- Created: 31 Oct 2011
- 544 KB
| Publication Part Number | A02203 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates several C2 to C5 free fatty acids in five minutes.
- Publication Part Number: A00078
- Created: 31 Oct 2011
- 574 KB
| Publication Part Number | A00078 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates 40 C2 to C20 free fatty acids in milk fat (with volatile acids added) in 60 minutes.
- Publication Part Number: A0362
- Created: 31 Oct 2011
- 881 KB
| Publication Part Number | A00362 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The Agilent J&W VF-200ms trifluoropropyl phase is very stable for analyzing aggressive compounds. Thick film loadability is much higher, as shown in more symmetrical peaks for
- Publication Part Number: A02214
- Created: 31 Oct 2011
- 664 KB
| Publication Part Number | A02214 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 58 FFAP CB column separates 19 components in a sample of natto (fermented soy beans) in 35 minutes.
- Publication Part Number: A0854
- Created: 31 Oct 2011
- 437 KB
| Publication Part Number | A00854 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-FFAP column separates nine C2 to C10 free fatty acids in a wine distillate in nine minutes.
- Publication Part Number: A0364
- Created: 31 Oct 2011
- 781 KB
| Publication Part Number | A00364 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W FFAP column separates eight volatile C2 to C7 free fatty acids in 15 minutes.
- Publication Part Number: A00097
- Created: 31 Oct 2011
- 561 KB
| Publication Part Number | A00097 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 58 CB column separates eight organic acids in nitrogen in 25 minutes.
- Publication Part Number: A1035
- Created: 31 Oct 2011
- 595 KB
| Publication Part Number | A01035 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|