Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
-
- Instrument
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
The sensitivity of UHPLC/MS method on an 6150 Series Single Quadrupole LC/MS was demonstrated for the application of cleaning verification studies of highly potent drugs.
- Publication Part Number: 5991-4509EN
- Created: 01 June 2014
- 1 MB
| Publication Part Number | 5991-4509EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Sample Class Prediction (SCP) models are powerful tools that can use mass spectrometry data from highly complex samples to identify differences in sample classes.
- Publication Part Number: 5991-0975EN
- Created: 02 Aug 2012
- 1 MB
| Publication Part Number | 5991-0975EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Specifically designed and tested Agilent J&W DB-Select 624UI for USP resolves critical pairs.
- Publication Part Number: 5991-0616EN
- Created: 07 June 2012
- 2 MB
| Publication Part Number | 5991-0616EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Using Agilent SPEC DAU for sample prep, and an Agilent J&W VF-DA, it was possible to determine hydroxy-alprazolam in Full Scan with confirmation by library search.
- Publication Part Number: A01982
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01982 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 26 pharmacopoeia-specified solvents in 30 minutes.
- Publication Part Number: A01304
- Created: 31 Oct 2011
- 845 KB
| Publication Part Number | A01304 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W VF-Xms column delivers symmetrical peaks with virtually no bleed in the analysis of cholestanyl derivatives.
- Publication Part Number: A01963
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01963 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC analysis of 14 USP 467 solvents on an Agilent J&W VF-200ms column takes 15 minutes.
- Publication Part Number: A02204
- Created: 31 Oct 2011
- 540 KB
| Publication Part Number | A02204 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB column separates six prostaglandins in 16 minutes.
- Publication Part Number: A0204
- Created: 31 Oct 2011
- 495 KB
| Publication Part Number | A00204 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q column separates four anesthetic gases in 18 minutes.
- Publication Part Number: A01627
- Created: 31 Oct 2011
- 403 KB
| Publication Part Number | A01627 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Separation of 21 TMS-derivatized sugars using gas chromatography and Agilent J&W VF-1ms in 36 minutes.
- Publication Part Number: A02337
- Created: 11 May 2010
- 651 KB
| Publication Part Number | A02337 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
本應(yīng)用簡(jiǎn)報(bào)介紹了如何像生物分析科學(xué)家進(jìn)行純度分析那樣,使用 Agilent Easy Access 軟件來分析模式治療性蛋白的批次間純度。
- Publication Part Number: 5991-3521CHCN
- Created: 11 Dec 2013
- 625 KB
| Publication Part Number | 5991-3521EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|