Gas chromatography using an Agilent J&W PoraPLOT Q column separates 11 C1 to C6 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0607
- Created: 31 Oct 2011
- 639 KB
CP7554+
| Publication Part Number | A00607 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates components in natural gas in 55 seconds.
- Publication Part Number: A0878
- Created: 31 Oct 2011
- 423 KB
| Publication Part Number | A00878 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight solvents in 25 minutes.
- Publication Part Number: A0608
- Created: 31 Oct 2011
- 626 KB
CP7554+
| Publication Part Number | A00608 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates 16 C5 to C8 hydrocarbon isomers in 220 seconds.
- Publication Part Number: A01628
- Created: 31 Oct 2011
- 344 KB
| Publication Part Number | A01628 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates gases in polyurethane in 14 minutes.
- Publication Part Number: A01355
- Created: 31 Oct 2011
- 585 KB
CP8567+
| Publication Part Number | A01355 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten propellants and solvents in aerosol containers in six minutes.
- Publication Part Number: A0333
- Created: 31 Oct 2011
- 1 MB
CP7516+
| Publication Part Number | A00333 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|