Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten C1 to C10 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A0225
- Created: 31 Oct 2011
- 611 KB
| Publication Part Number | A00225 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates eight components in a sample of natural gas in 30 minutes.
- Publication Part Number: A01354
- Created: 31 Oct 2011
- 786 KB
| Publication Part Number | A01354 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
| Publication Part Number | A00271 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C1 to C7 hydrocarbons in natural gas in 25 minutes.
- Publication Part Number: A0117
- Created: 31 Oct 2011
- 588 KB
| Publication Part Number | A00117 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C8 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A00226
- Created: 31 Oct 2011
- 628 KB
| Publication Part Number | A00226 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
使用雙 FID 和微板流路技術(shù)中心切割 (Deans Switch) 在室溫下分析 C1 到 C10 烴類,包括 C1 到 C6 的鏈烷烴/烯烴異構(gòu)體分離
- Publication Part Number: 5991-3253CHCN
- Created: 27 Sep 2013
- 2 MB
| Publication Part Number | 5991-3253EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
本實(shí)驗(yàn)建立了使用毛細(xì)管柱、單個(gè)閥、單個(gè)TCD 檢測器、微板流路控制技術(shù)(CFT) Deans Switch 系統(tǒng)進(jìn)行氣態(tài)和液態(tài)天然氣的分析方法。
- Publication Part Number: 5991-2063CHCN
- Created: 20 June 2013
- 256 KB
| Publication Part Number | 5991-2063EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||