Refine Results
- Content Type
-
Content Type
- Analyzed With
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
HPLC separation of peptide standards with an Agilent Polaris C18-A column delivers base-line separation between leucine enkephalin and angiotensin II.
- Publication Part Number: A02056
- Created: 31 Oct 2011
- 446 KB
A2000150C046+A2000150X046+
| Publication Part Number | A02056 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Excellent selectivity, sharp peaks, and high resolution between very similar peptides is achieved when using HPLC with Agilent Polaris C18-A.
- Publication Part Number: A02057
- Created: 31 Oct 2011
- 539 KB
A2000150C046+A2000150X046+
| Publication Part Number | A02057 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
HPLC separation of five cationic peptide standards with an Agilent Polaris C18-A column is achieved in16 minutes.
- Publication Part Number: A02055
- Created: 31 Oct 2011
- 513 KB
A2000150C046+A2000250X046+
| Publication Part Number | A02055 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
HPLC of peptides is straightforward with an Agilent Polaris C18 Ether column in four minutes.
- Publication Part Number: A02302
- Created: 11 May 2010
- 513 KB
A2020150X046+
| Publication Part Number | A02302 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
HPLC separation of two glutathiones takes four minutes with Agilent Pursuit C18.
- Publication Part Number: A02300
- Created: 11 May 2010
- 700 KB
A3000150X046+
| Publication Part Number | A02300 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Separation of insulin genetic variants (n-mer from n-1 mers) is achieved by Agilent Pursuit C18 with HPLC.
- Publication Part Number: A02301
- Created: 11 May 2010
- 539 KB
A3000250X046+
| Publication Part Number | A02301 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|