Analysis of multiple semi-volatile organic compounds by USEPA method 8270D is challenging. It was performed by GC/MS with FactorFour VF-5ms column and quadrupole MS, giving 7
- Publication Part Number: SI-2365
- Created: 01 Aug 2013
- 253 KB
CP8944+
| Publication Part Number | SI-02365 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
122-9732+
| Publication Part Number | 5991-2153EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
GC analysis of 14 base neutrals with an Agilent J&W VF-200ms column achieves a separation in 28 minutes.
- Publication Part Number: A02200
- Created: 31 Oct 2011
- 617 KB
CP8858+
| Publication Part Number | A02200 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Analysis of 14 base neutrals by gas chromatography using an Agilent J&W VF-1301ms column in less than 40 minutes.
- Publication Part Number: A02414
- Created: 11 May 2010
- 720 KB
CP9053+
| Publication Part Number | A02414 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|