Refine Results
- Applications and Industries
- Content Type
-
Applications (4)
Content Type
- Analysis Technique
- Chemical Group
- Compounds
-
- Instrument
- Analysis Platform
-
Intelligent System Emulation Technology (ISET) (1) 1290 Infinity Method Development System NEW (1) 1290 Infinity II Method Development System (archive) (1)
Product
- Language
-
English (4)
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
A quality-by-design (QbD) approach to method development can potentially lead
- Publication Part Number: 5991-3834EN
- Created: 01 Feb 2014
- 727 KB
757700-302+857700-302+857700-312+857768-901+959757-306+PL1512-1300+
| Publication Part Number | 5991-3834EN | |||||||
|---|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||||
| Instrument |
|
|||||||
| Analytical Technique | Technique |
|
||||||
| Injection |
|
|||||||
| Detection |
|
|||||||
| Sample | Chemical Group |
|
||||||
| Sample Matrix |
|
Ocycodone and its oxidative metabolites are analyzed by high performance HPLC/MS coupled with chromatographic separation by an Agilent ZORBAX RRHT Stablebond SB-C18 column.
- Publication Part Number: 5990-3815EN
- Created: 05 Feb 2013
- 92 KB
827700-902+
| Publication Part Number | 5990-3815EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The Agilent 1290 Infinity LC System Method Development Solution was used to find optimum separation conditions for degra?dation products of a pharmaceutical preparation.
- Publication Part Number: 5991-0989EN
- Created: 01 Aug 2012
- 1 MB
727700-902+827700-902+827700-905+827700-906+827700-912+
| Publication Part Number | 5991-0989EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
This application note describes the ways in which RRHD columns allow for selectivity refinement of methods for selected endocannabinoids.
- Publication Part Number: 5990-7166EN
- Created: 21 Mar 2011
- 251 KB
758700-902+858700-902+959758-902+981758-902+
| Publication Part Number | 5990-7166EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|