Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Injection Technique
- Instrument
- Language
-
Language
Application note for the multi-residue analysis for PAHs, PCBs and OCPs on FactorFour VF-200ms
- Publication Part Number: SI-02467
- Created: 30 Jan 2014
- 348 KB
| Publication Part Number | SI-02467 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Application note for the multi-residue analysis of PAHs, PCBs and OCPs using an Agilent FactorFour VF-35ms Column
- Publication Part Number: SI-2396
- Created: 30 Jan 2014
- 274 KB
| Publication Part Number | SI-02396 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Multi-residue analysis of PAHs, PCBs and OCPs was performed using GC/MS with Agilent J&W FactorFour VF-Xms column, demonstrating separation
- Publication Part Number: SI-02443
- Created: 09 Aug 2013
- 302 KB
| Publication Part Number | SI-02443 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Polycyclic aromatic hydrocarbons (PAHs) are often analyzed with other environmental pollutants, such as polychlorinated...
- Publication Part Number: SI-2438
- Created: 09 July 2013
- 458 KB
| Publication Part Number | SI-02438 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
A highly sensitive and reliable method has been developed for 51 nonpolar compounds in potable water, and PBDEs, PAHs, and diazinon in wastewater.
- Publication Part Number: 5991-1553EN
- Created: 16 Jan 2013
- 1 MB
| Publication Part Number | 5991-1553EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Multi-residue analysis of PAHs, PCBs and OCPs in environmental samples using a GC-MS with a FactorFour VF-5ms column and quadrupole MS.
- Publication Part Number: SI-2364
- Created: 26 Sep 2012
- 167 KB
| Publication Part Number | SI-02364 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 60 pesticides and polycyclic biphenyls in 24 minutes.
- Publication Part Number: A0709
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A00709 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
| Publication Part Number | A00596 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 23 pesticides and polychlorinated biphenyls in a standard mixture in 26 minutes.
- Publication Part Number: A0478
- Created: 31 Oct 2011
- 699 KB
| Publication Part Number | A00478 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Separation of 30 polychlorinated biphenyls and pesticides is achieved by gas chromatography with highly apolar Agilent J&W CP-Sil 5/C18 for PCB in 46 minutes.
- Publication Part Number: A01506
- Created: 31 Oct 2011
- 688 KB
| Publication Part Number | A01506 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB/C18 column separates organic pollutants in whale blubber in 95 minutes.
- Publication Part Number: A0978
- Created: 31 Oct 2011
- 822 KB
| Publication Part Number | A00978 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Exploring techniques for determining chemical contaminants in marine shellfish using the Agilent 7000 Triple Quadrupole GC/MS System.
- Publication Part Number: 5990-7714EN
- Created: 06 Apr 2011
- 857 KB
| Publication Part Number | 5990-7714EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|