Refine Results
- Products
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF
- Publication Part Number: 5991-4369EN
- Created: 02 May 2014
- 2 MB
| Publication Part Number | 5991-4369EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
At a rate of 10 seconds per sample, RapidFire/MS is suitable for ultrafast determination of IC50 curves of potential inhibitors of CYP3A4, CYP2C9, and CYP2D6
- Publication Part Number: 5991-3693EN
- Created: 05 Dec 2013
- 655 KB
| Publication Part Number | 5991-3693EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
HPLC analysis of four antihistamines and an impurity is achieved with an Agilent Polaris C18-A column in under three minutes.
- Publication Part Number: A02013
- Created: 31 Oct 2011
- 685 KB
| Publication Part Number | A02013 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
HPLC using an Agilent Polaris C18-A column separates four components of a cold medicine in under four minutes
- Publication Part Number: A02010
- Created: 31 Oct 2011
- 627 KB
| Publication Part Number | A02010 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
HPLC analysis of six actives in a children’s medication for colds and ‘flu’ is achieved with an Agilent Polaris C18-A column in less than four minutes.
- Publication Part Number: A02009
- Created: 31 Oct 2011
- 608 KB
| Publication Part Number | A02009 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
LC/MS with an Agilent Polaris C18-A column analyzes cold and cough medicine in less than four minutes.
- Publication Part Number: A01931
- Created: 01 Oct 2011
- 663 KB
| Publication Part Number | A01931 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
473C.jpg
- Publication Part Number: 883975-905
- Created: 08 May 2018
- 44 KB
- JPG
| Publication Part Number | 473C | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
510B.jpg
- Publication Part Number: 993967-906
- Created: 08 May 2018
- 29 KB
- JPG
| Publication Part Number | 510B | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
- Publication Part Number: 866953-902
- Created: 20 Dec 2005
- 30 KB
| Publication Part Number | NNLC015 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|