GC with Agilent J&W CP-SilicaPLOT analyzes sulfur (to about 0.05 to 0.1 ppm) and hydrocarbosn in beverage-grade CO2; aromatic and acetaldehyde hydrocarbons < 1 ppbv.
- Publication Part Number: A01644
- Created: 31 Oct 2011
- 385 KB
| Publication Part Number | A01644 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB for Sulfur column separates three sulfides in exhaust gas in four minutes.
- Publication Part Number: A01319
- Created: 31 Oct 2011
- 552 KB
| Publication Part Number | A01319 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column elutes sulfur gases without interference from light hydrocarbons, in ten minutes.
- Publication Part Number: A01292
- Created: 31 Oct 2011
- 791 KB
| Publication Part Number | A01292 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC using an Agilent J&W CP-Sil 5 CB separates three sulfur gases, hydrogen sulfide, carbonyl sulfide, and methyl mercaptan, from natural gas according to ASTM D5504.
- Publication Part Number: A01643
- Created: 31 Oct 2011
- 531 KB
| Publication Part Number | A01643 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates four sulfur contaminants in beverage-grade carbon dioxide in less than nine minutes.
- Publication Part Number: A01626
- Created: 31 Oct 2011
- 425 KB
| Publication Part Number | A01626 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column identifies trace sulfides in propylene in less than three minutes.
- Publication Part Number: A01293
- Created: 31 Oct 2011
- 570 KB
| Publication Part Number | A01293 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Publication Part Number | C654 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|