Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Instrument
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
An Agilent7820 GC method for Acetaldehyde residue in PET bottled was developed .
- Publication Part Number: 5991-4355EN
- Created: 28 Mar 2014
- 120 KB
| Publication Part Number | 5991-4355EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Following the European Standard EN 71 part 11, an economical solution for the determination of VOCs was developed on a 7820A GC with a 5977E GC/MSD Sys configured to a 7667A
- Publication Part Number: 5991-3604EN
- Created: 15 Nov 2013
- 133 KB
| Publication Part Number | 5991-3604EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Agilent 5977EGCMS shows good performance on phthalates analysis
- Publication Part Number: 5991-3330EN
- Created: 18 Oct 2013
- 275 KB
| Publication Part Number | 5991-3330EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
A multiple headspace extraction (MHE) method using the 7697A Headspace Sampler coupled with a 7890A GC has been developed for quantitative dertermination of residual monomers.
- Publication Part Number: 5991-0974EN
- Created: 10 Aug 2012
- 981 KB
| Publication Part Number | 5991-0974EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Residual monomers are determined in a series of polymers including poly methyl methacrylate, poly acrylic, styrene co-methyl methacrylate, and styrene co-butadiene.
- Publication Part Number: 5991-0342EN
- Created: 31 May 2012
- 1 MB
| Publication Part Number | 5990-0342EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
代謝物富集的餾分收集、兩相溶劑萃取、互補(bǔ)的色譜柱化學(xué)鍵合相以及液質(zhì)聯(lián)用和氣質(zhì)聯(lián)用檢測,促使分析可涵蓋更多的代謝物。
- Publication Part Number: 5991-4663CHCN
- Created: 01 June 2014
- 1 MB
| Publication Part Number | 5991-4663EN | |||||||
|---|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||||
| Instrument |
|
|||||||
| Analytical Technique | Technique |
|
||||||
| Injection |
|
|||||||
| Detection |
|
|||||||
| Sample | Chemical Group |
|
||||||
| Sample Matrix |
|
使用雙 FID 和微板流路技術(shù)中心切割 (Deans Switch) 在室溫下分析 C1 到 C10 烴類,包括 C1 到 C6 的鏈烷烴/烯烴異構(gòu)體分離
- Publication Part Number: 5991-3253CHCN
- Created: 27 Sep 2013
- 2 MB
| Publication Part Number | 5991-3253EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|