Separation of 30 polychlorinated biphenyls and pesticides is achieved by gas chromatography with highly apolar Agilent J&W CP-Sil 5/C18 for PCB in 46 minutes.
- Publication Part Number: A01506
- Created: 31 Oct 2011
- 688 KB
CP7477+
| Publication Part Number | A01506 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB column separates 15 organochlorine pesticides in 29 minutes.
- Publication Part Number: A01109
- Created: 31 Oct 2011
- 623 KB
CP5871+
| Publication Part Number | A01109 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS of 15 pesticides is achieved in 20 minutes using an Agilent J&W CP-Sil 8 CB column.
- Publication Part Number: A01656
- Created: 31 Oct 2011
- 688 KB
CP8751+
| Publication Part Number | A01656 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 29 pesticides according to EPA 508 in 64 minutes.
- Publication Part Number: A0780
- Created: 31 Oct 2011
- 551 KB
CP7481+
| Publication Part Number | A00780 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
CP5817+
| Publication Part Number | A01503 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
利用Agilent 7000 三重四極桿GC/MS完成水中非極性有機化合物的高靈敏度 GC/MS/MS 分析
- Publication Part Number: 5991-1553CHCN
- Created: 16 Jan 2013
- 1 MB
122-0132+
| Publication Part Number | 5991-1553EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
使用安捷倫特殊設(shè)計的J&W DB-UI 8270D 色譜柱分析半揮發(fā)性組分
- Publication Part Number: 5991-0250CHCN
- Created: 24 Aug 2012
- 700 KB
121-9723+122-9732+
| Publication Part Number | 5991-0250EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|