Refine Results
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Injection Technique
-
- Method
-
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01017 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
| Publication Part Number | A01322 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 C1 to C10 aromatic hydrocarbons in 23 minutes.
- Publication Part Number: A0351
- Created: 31 Oct 2011
- 911 KB
| Publication Part Number | A00351 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of mineral oil in soil or water is achieved in eight minutes with an Agilent J&W Select Mineral Oil column, allowing determination of C10 to C40.
- Publication Part Number: A02016
- Created: 31 Oct 2011
- 587 KB
| Publication Part Number | A02016 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
With large volume injection method, C10 to C40 mineral oils in water are determined in less than 15 minutes at ppb levels with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01977
- Created: 31 Oct 2011
- 943 KB
| Publication Part Number | A01977 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The Agilent 1079 PTV injector with specially designed liner quantifies mineral oils down to ppb levels without preconcentration.
- Publication Part Number: A02460
- Created: 11 May 2010
- 2 MB
| Publication Part Number | A02460 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The Agilent 1079 PTV injector with optimized liner allows the quantitative determination of mineral oils down to ppb levels using the large volume injection technique.
- Publication Part Number: A02461
- Created: 11 May 2010
- 5 MB
| Publication Part Number | A02461 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|