Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
Application note describes innovative method for the confirmation of fire accelerants using the Agilent Capillary Trap Sampler (CTS).
- Publication Part Number: 5991-3439EN
- Created: 12 Dec 2013
- 250 KB
| Publication Part Number | 5991-3439EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Gas chromatography with an Agilent J&W CP-Sil 8 CB column investigates the storage conditions of carbonated water, identifying 15 components in 30 minutes.
- Publication Part Number: A1015
- Created: 31 Oct 2011
- 565 KB
CP7769+
| Publication Part Number | A01015 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC separation of 37 oxygenated compounds on a highly selective Agilent J&W Lowox multilayer column is achieved in 45 minutes.
- Publication Part Number: A02251
- Created: 31 Oct 2011
- 874 KB
CP8587+
| Publication Part Number | A02251 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 22 components in a raw material for plastic packaging in 20 minutes.
- Publication Part Number: A1016
- Created: 31 Oct 2011
- 648 KB
CP7769+
| Publication Part Number | A01016 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 27semivolatiles in indoor air in 40 minutes.
- Publication Part Number: A01901
- Created: 01 Oct 2011
- 1 MB
CP7751+
| Publication Part Number | A01901 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|