Refine Results
- Products
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Detection Technique
-
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 12 triazine herbicides in 16 minutes.
- Publication Part Number: A0910
- Created: 31 Oct 2011
- 661 KB
| Publication Part Number | A00910 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates seven polar N-herbicides in 25 minutes.
- Publication Part Number: A01111
- Created: 31 Oct 2011
- 425 KB
| Publication Part Number | A01111 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 triazine herbicides in 30 minutes.
- Publication Part Number: A01227
- Created: 31 Oct 2011
- 372 KB
| Publication Part Number | A01227 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
| Publication Part Number | A01503 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Analysis of 25 herbicides and herbicide metabolites in different environmental water samples using the Agilent 1200 Infinity Series Online SPE Solution.
- Publication Part Number: 5991-2773RU
- Created: 18 Nov 2014
- 454 KB
| Publication Part Number | 5991-2773EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
使用配有Agilent J&WDB-5ms 超高惰性低熱容色譜柱模塊的Agilent 5975T LTMGC/MSD 成功分析了水樣中的多種農(nóng)藥
- Publication Part Number: 5991-4264CHCN
- Created: 14 Mar 2014
- 474 KB
| Publication Part Number | 5991-4264EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
使用 LC/MS 分別通過直接進(jìn)樣和在線SPE 進(jìn)行水中痕量除草劑定量分析的比較研究
- Publication Part Number: 5991-2140CHCN
- Created: 01 Nov 2013
- 1 MB
| Publication Part Number | 5991-2140EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
關(guān)于使用 Agilent 1200 Infinity 系列在線固相萃取解決方案檢測飲用水、地表水和地下水中痕量除草劑的實驗室間的驗證性研究
- Publication Part Number: 5991-2405CHCN
- Created: 01 June 2013
- 610 KB
| Publication Part Number | 5991-2405EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|