Application note for the analysis of Pesticide Residues in Apple by GC/MS using Agilent Bond Elut QuEChERS Kits for Preinjection Cleanup
- Publication Part Number: 5990-4468EN
- Created: 06 Jan 2012
- 217 KB
| Publication Part Number | 5990-4468EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 19 pesticides and herbicides according to EPA 507 in 37 minutes.
- Publication Part Number: A0911
- Created: 31 Oct 2011
- 719 KB
| Publication Part Number | A00911 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates nine organophosphate pesticides in 15 minutes.
- Publication Part Number: A0358
- Created: 31 Oct 2011
- 695 KB
| Publication Part Number | A00358 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with Agilent J&W CP-Sil 8 CB and PFPD is a highly sensitive and selective system capable of detecting a number of elements, 13 of these with ultimate selectivity.
- Publication Part Number: A01608
- Created: 31 Oct 2011
- 4 MB
| Publication Part Number | A01608 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
| Publication Part Number | A01002 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Sil 8 CB column separates 14 organophosphorus pesticides in 27 minutes.
- Publication Part Number: A01108
- Created: 31 Oct 2011
- 461 KB
| Publication Part Number | A01108 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 25 organophosphorus pesticides according to EPA 8140 and 8141 in 31 minutes.
- Publication Part Number: A0615
- Created: 31 Oct 2011
- 867 KB
| Publication Part Number | A00615 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC/MS using an Agilent J&W CP-Sil 24 CB Low Bleed/MS column delivers highly selective trace analysis of 23 pesticide residues in surface water in 23 minutes.
- Publication Part Number: A01503
- Created: 31 Oct 2011
- 809 KB
| Publication Part Number | A01503 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|