Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
- Injection Technique
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
Application note for Agilent Hi-Plex Columns for Carbohydrates, Alcohols, and Acids
- Publication Part Number: 5990-8264EN
- Created: 11 Feb 2014
- 220 KB
PL1170-6810+PL1170-6830+
| Publication Part Number | 5990-8264EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The separation of seven sugar alcohols or polyols on an the Hi-Plex Ca column can be altered by introducing acetonitrile into the mobile phase.
- Publication Part Number: SI-01672
- Created: 11 Jan 2013
- 189 KB
PL1570-5810+
| Publication Part Number | SI-01672 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC/MS with an Agilent J&W CP-Chirasil-DEX CB column separates arabitol enantiomers as trifluoroacetyl derivatives in spinal fluid in 11 minutes.
- Publication Part Number: A01422
- Created: 31 Oct 2011
- 451 KB
CP7502+
| Publication Part Number | A01422 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W VF-23ms column separates nine alditol acetates in four minutes.
- Publication Part Number: A01969
- Created: 31 Oct 2011
- 628 KB
CP8822+
| Publication Part Number | A01969 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W VF-23ms column separates eight alditol acetates in nine minutes.
- Publication Part Number: A01968
- Created: 31 Oct 2011
- 628 KB
CP8830+
| Publication Part Number | A01968 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Separation of 21 TMS-derivatized sugars using gas chromatography and Agilent J&W VF-1ms in 36 minutes.
- Publication Part Number: A02337
- Created: 11 May 2010
- 651 KB
CP8912+
| Publication Part Number | A02337 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|