Refine Results
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Compounds
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
This application note describes a method for fast on-site analysis of mine gases in less than 100 seconds using the Agilent 490 Micro GC.
- Publication Part Number: 5991-0438EN
- Created: 06 June 2012
- 753 KB
| Publication Part Number | 5991-0438EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Fast GC analysis of refrigerant impurities in CFC-22 is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01959
- Created: 31 Oct 2011
- 560 KB
| Publication Part Number | A01959 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography with a four-channel Agilent 490 Micro GC separates constituents of mine gas, including carbon monoxide, in 120 seconds.
- Publication Part Number: A01789
- Created: 31 Oct 2011
- 614 KB
| Publication Part Number | A01789 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Fast GC analysis of refrigerant impurities in CFC-143A is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01958
- Created: 31 Oct 2011
- 520 KB
| Publication Part Number | A01958 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column and Agilent 490 Micro GC separates oxygen and nitrogen in 40 seconds.
- Publication Part Number: A02061
- Created: 31 Oct 2011
- 678 KB
| Publication Part Number | A02061 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Fast GC analysis of halogenated refrigerant mixtures is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01957
- Created: 31 Oct 2011
- 564 KB
| Publication Part Number | A01957 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the analysis of Volatile Solvents on CP-Sil 5 CB using the Agilent 490 Micro GC
- Publication Part Number: 5990-8699EN
- Created: 25 July 2011
- 254 KB
| Publication Part Number | 5990-8699EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|