Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Compounds
-
- Language
-
Language
Applied Filters
The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5?.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
| Publication Part Number | A01621 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5? analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
| Publication Part Number | A01619 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01238
- Created: 31 Oct 2011
- 357 KB
| Publication Part Number | A01238 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01237
- Created: 31 Oct 2011
- 343 KB
| Publication Part Number | A01237 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC determines impurities in nitrogen in 150 seconds.
- Publication Part Number: A01242
- Created: 31 Oct 2011
- 382 KB
| Publication Part Number | A01242 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|