Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
This Application Note describes the analysis of hydrophilic phenolic compounds in olive oil samples, using both HPLC and UHPLC with ternary gradients on the Agilent 1260 Infin
- Publication Part Number: 5991-3801EN
- Created: 01 May 2014
- 855 KB
| Publication Part Number | 5991-3801EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Demonstration of the Agilent 1290 Infinity 2D-LC Solution to resolve the hydrophilic phenols in virgin olive oils and investigation of differences between olive oils.
- Publication Part Number: 5991-4515EN
- Created: 01 May 2014
- 3 MB
| Publication Part Number | 5991-4515EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Emulation of Waters Alliance 2695 LC for analysis of aromatic acids using Agilent 1290 Infinity Binary LC with ISET.
- Publication Part Number: 5991-2019EN
- Created: 01 Apr 2013
- 1 MB
| Publication Part Number | 5991-2019EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
2-Dimensional separation of polyphenols in beverages using the Agilent 1290 Infinity 2D-LC Solution and software-assisted 2D-LC data analysis for comparison of ingredients.
- Publication Part Number: 5991-1455EN
- Created: 01 Jan 2013
- 1 MB
| Publication Part Number | 5991-1455EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A Waters method for the analysis of aromatic acids was improved when transferred to an Agilent 1290 Infinity LC with an Agilent ZORBAX RRHD column
- Publication Part Number: 5991-1681EN
- Created: 27 Nov 2012
- 244 KB
| Publication Part Number | 5991-1681EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This Application Note demonstrates the Agilent 1290 Infinity 2D-LC Solution for resolving complex mixtures by reversed-phase/reversed-phase, two-dimensional chromatography.
- Publication Part Number: 5991-0426EN
- Created: 01 May 2012
- 2 MB
| Publication Part Number | 5991-0426EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|