Fifteen days’ exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
| Publication Part Number | 5991-4110EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The Agilent Inert Flow Path outperformed a non-Agilent version for trace pesticides, with less impact on analytes and better results for some critical pesticides.
- Publication Part Number: 5991-3234EN
- Created: 19 Sep 2013
- 925 KB
| Publication Part Number | 5991-3234EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Agilent Ultra Inert liners with wool give accurate and precise pesticide trace levels from 5 μL extracts in acetonitrile.
- Publication Part Number: 5991-1196EN
- Created: 04 Oct 2012
- 1 MB
| Publication Part Number | 5991-1196EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Agilent J&W DB-CLP1 and DB-CLP2 column pair performs rapid, high-resolution separations of CLP pesticides, US EPA methods, and similar semi-volatile mixtures
- Publication Part Number: 5991-0541EN
- Created: 06 Aug 2012
- 482 KB
| Publication Part Number | 5991-0541EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Compared to other vendor’s columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
| Publication Part Number | 5991-0615EN | |||||||
|---|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||||
| Instrument |
|
|||||||
| Analytical Technique | Technique |
|
||||||
| Injection |
|
|||||||
| Detection |
|
|||||||
| Sample | Chemical Group |
|
||||||
| Sample Matrix |
|
Application note for the analysis of pesticide residues in apple using Agilent Bond Elut QuEChERS AOAC Kits by GC/MS
- Publication Part Number: 5990-4068EN
- Created: 06 Jan 2012
- 113 KB
| Publication Part Number | 5990-4068EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
Application note for GC-μECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil