Refine Results
- Content Type
-
Content Type
- Analyzed With
- Method
- Language
-
Language
Applied Filters
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
Fast GC analysis of lubricating oil contamination in under ten minutes using an Agilent J&W Select Mineral Oil column according to DIN EN ISO 9377-2.
- Publication Part Number: A02048
- Created: 31 Oct 2011
- 684 KB
CP7491+
| Publication Part Number | A02048 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The analysis of mineral oil to DIN EN ISO 9377-2 is accomplished by GC with an Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02045
- Created: 31 Oct 2011
- 726 KB
CP7491+
| Publication Part Number | A02045 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
With large volume injection method, C10 to C40 mineral oils in water are determined in less than 15 minutes at ppb levels with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01977
- Created: 31 Oct 2011
- 943 KB
| Publication Part Number | A01977 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Fast analysis of diesel-contaminated samples is achieved by GC with the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02047
- Created: 31 Oct 2011
- 1 MB
CP7491+
| Publication Part Number | A02047 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
CP7859+
| Publication Part Number | A01322 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|